2018
DOI: 10.1016/j.carbon.2018.07.004
|View full text |Cite
|
Sign up to set email alerts
|

Multifunctional fluorescent “Off-On-Off” nanosensor for Au3+ and S2− employing N-S co-doped carbon–dots

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
44
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 88 publications
(44 citation statements)
references
References 60 publications
0
44
0
Order By: Relevance
“…The system is sensitive to Cu 2+ ions over a concentration range of 2–80 × 10 −9 m , with a limit of detection of 1.8 × 10 −9 m . C dots prepared from rose petals with the addition of ethylenediamine as nitrogen‐dopant and cysteine as sulfur‐dopant were used to determine S 2− down to 92.4 × 10 −9 m based on the analyte induced fluorescence enhancement . Further addition of Au 3+ quenched the fluorescence of the C dots, which allowed detection of Au 3+ with LOD of 63.1 × 10 −9 m .…”
Section: Sensing and Imaging Applicationsmentioning
confidence: 99%
“…The system is sensitive to Cu 2+ ions over a concentration range of 2–80 × 10 −9 m , with a limit of detection of 1.8 × 10 −9 m . C dots prepared from rose petals with the addition of ethylenediamine as nitrogen‐dopant and cysteine as sulfur‐dopant were used to determine S 2− down to 92.4 × 10 −9 m based on the analyte induced fluorescence enhancement . Further addition of Au 3+ quenched the fluorescence of the C dots, which allowed detection of Au 3+ with LOD of 63.1 × 10 −9 m .…”
Section: Sensing and Imaging Applicationsmentioning
confidence: 99%
“…Peaks in the range of 170-180 ppm, which correspond to carboxyl/amide groups, were seen in the spectrum of the N-S@RCD samples. 2,3 To support the explanations derived from 1D NMR, 2D NMR homo ( 1 H/ 1 H) and hetero ( 13 C/ 1 H) correlation were studied with the help of HMBC and COSY NMR, respectively, for RE, NSR-1 h/ 2 h/3 h/4 h and N-S@RCD samples (Fig. 3).…”
mentioning
confidence: 95%
“…The fluorescence switching behavior of CBCDs in the presence of Fe 3+ and AA can be employed as multiple molecular logic gates, performing the Boolean algebraic logic operations. 62 The simple single input molecular logic gate NOT can be constructed using Fe 3+ as single input signal ( Figure 7 a). The multiple input logic gate IMPLICATION can be realized by taking Fe 3+ and AA as input 1 and input 2, respectively.…”
Section: Resultsmentioning
confidence: 99%