2022
DOI: 10.1021/acsabm.1c01278
|View full text |Cite
|
Sign up to set email alerts
|

Multifaceted Interaction Studies between Carbon Dots and Proteins of Clinical Importance for Optical Sensing Signals

Abstract: Carbon dots (CDs) are emerging as efficient optical probes. However, their application potential for clinical diagnosis has not been adequately explored. Herein, we examined the suitability of pyroglutamate CDs for detecting glucose, cholesterol, and alcohol in blood serum through their peroxidative activity in the respective enzyme-catalyzed reactions following fluorometric and colorimetric approaches. In buffer, the CD’s fluorescence intensity (λex 354nm) enhanced over 115% after interaction with the enzyme … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 25 publications
0
7
0
Order By: Relevance
“…Serum samples were diluted 500 times during the assay to effectively reduce interference from complex matrices. We learned that serum may affect the optical properties of CDs in related work [27] . For example, Smita Das et al.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Serum samples were diluted 500 times during the assay to effectively reduce interference from complex matrices. We learned that serum may affect the optical properties of CDs in related work [27] . For example, Smita Das et al.…”
Section: Methodsmentioning
confidence: 99%
“…We learned that serum may affect the optical properties of CDs in related work. [27] For example, Smita Das et al found the CDs' fluorescence in the blood serum medium was also enhanced where serum's particulate components contributed to the emission. When CDs were mixed with diluted serum, the fluorescence of CDs was significantly increased compared with that of CDs in the buffer system.…”
Section: Real Sample Detectionmentioning
confidence: 99%
“…Nevertheless, a FL sensor renders much more flexibility in terms of simple instrumentation/operation, fast responses, multiple analyses, high sensitivity, and good selectivity with ample scopes to attune CDs as required. Furthermore, a wide range of cheaper sources with green synthesis routes such as hydrothermal methods have also been explored to date for making them more reliable in practical applications. , …”
Section: Introductionmentioning
confidence: 99%
“…Furthermore, a wide range of cheaper sources with green synthesis routes such as hydrothermal methods have also been explored to date for making them more reliable in practical applications. 31,32 Though many attempts have already been made for sensing of a range of contaminants including heavy metals by differently functionalized CDs, very few works particularize a detailed investigation of physicochemical attributes of CDs responsible for their heavy-metal sensing behavior. Herein, a deliberate attempt has been made to understand how reduction could affect the surface functionalities for tuning useful photophysical attributes to be used for the speciation of heavy metals (Co 2+ and Hg 2+ ) and their dual sensing at trace levels.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation