2005
DOI: 10.1016/j.talanta.2004.09.001
|View full text |Cite
|
Sign up to set email alerts
|

Multielemental characterisation of cobalt by glow discharge quadrupole mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2006
2006
2021
2021

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 6 publications
0
5
0
Order By: Relevance
“…Selenium species [Se(IV) and Se(VI)] were estimated in tube-well water samples by ion chromatography coupled with ICP-MS and also by a UV-assisted vapor generation combined with a sensitive "collect and punch"-ICP-MS method. Similarly, the possibility of using moss (Funaria hygrometrica), immobilized in a polysilicate matrix as the substrate for speciation of Cr(III) and Cr(VI) in various water samples was studied by using ICP-MS. [376][377][378][379][380][381][382][383][384][385][386][387][388][389][390] The "collect and punch" cold vapor ICP-MS method was also developed for the direct determination of mercury at nanograms per liter levels. 391 An ultrasound-assisted extraction procedure for the fast estimation of major, minor and trace elements in lichen and mussel samples was developed and ICP-MS was used to estimate elements such as Na, K, Ca, Mg, Cr, Mn, Co, Ni, Cu, Zn, Ge, As, Se, Rb, Sr, Zr, Ag, Cd, In, Sb, Cs, Ba, Pb and Bi.…”
Section: Nuclear Chemistrymentioning
confidence: 99%
“…Selenium species [Se(IV) and Se(VI)] were estimated in tube-well water samples by ion chromatography coupled with ICP-MS and also by a UV-assisted vapor generation combined with a sensitive "collect and punch"-ICP-MS method. Similarly, the possibility of using moss (Funaria hygrometrica), immobilized in a polysilicate matrix as the substrate for speciation of Cr(III) and Cr(VI) in various water samples was studied by using ICP-MS. [376][377][378][379][380][381][382][383][384][385][386][387][388][389][390] The "collect and punch" cold vapor ICP-MS method was also developed for the direct determination of mercury at nanograms per liter levels. 391 An ultrasound-assisted extraction procedure for the fast estimation of major, minor and trace elements in lichen and mussel samples was developed and ICP-MS was used to estimate elements such as Na, K, Ca, Mg, Cr, Mn, Co, Ni, Cu, Zn, Ge, As, Se, Rb, Sr, Zr, Ag, Cd, In, Sb, Cs, Ba, Pb and Bi.…”
Section: Nuclear Chemistrymentioning
confidence: 99%
“…Glow discharge mass spectrometry (GD-MS), which is an efficient direct solid analysis method, [2][3][4][5][6][7][8] has been developed rapidly since the 1980s, 9 especially in the trace analysis of high pure metal and semiconductor materials. [10][11][12][13][14][15][16][17][18][19][20] the advantages of GD-MS are its ability to determine almost all elements, superior detection limits, multi-elemental analysis, little matrix effect and wide linear dynamic range. [21][22][23] the interferences, which include isobars, multi-charge ions and multi-atom ions generated by the discharge gas, matrices and alloy elements, have a serious effect on the determination of trace elements, so the main problem is to eliminate the mass spectral interference for the determination of trace elements in the superalloy by GD-MS.…”
Section: Journal Of Mass Spectrometrymentioning
confidence: 99%
“…GDMS is considered to be the most effective method for the direct determination of trace and ultra-trace elements in solid conductive materials 24 and is widely used in the analysis of metals, alloys, semiconductors, etc. [25][26][27][28][29][30][31][32] In an analysis, the interference affects the accuracy of the results, so mass spectrometric interferences should be fully considered in GDMS analysis, 21-22, 27, 33-35 especially for a complex matrix. The main interferences in GDMS analysis are heterotopic interference, polyatomic ion interference and multi-charge ion interference.…”
Section: Introductionmentioning
confidence: 99%
“…When no suitable certified reference material can be found, the RSF obtained from one matrix reference material can be used to analyze another matrix sample. [25][26][27] In recent years, scholars have done more research on RSF. [36][37] However, the experimental results show that some elements in some matrices cannot provide satisfactory results after being corrected by RSF obtained from different matrix reference materials.…”
Section: Introductionmentioning
confidence: 99%