2014
DOI: 10.1016/j.foodchem.2014.03.041
|View full text |Cite
|
Sign up to set email alerts
|

Multielemental analysis in vegetable edible oils by inductively coupled plasma mass spectrometry after solubilisation with tetramethylammonium hydroxide

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
25
1

Year Published

2014
2014
2021
2021

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 44 publications
(29 citation statements)
references
References 36 publications
3
25
1
Order By: Relevance
“…Significant difference between different sets of data from different regions was defined as p < 0.05 (Zhao et al, 2011(Zhao et al, , 2013. Principal component analysis (PCA) is a method for linear data analysis and is known for its capability to reduce the dimensionality of the data (Kropf et al, 2010;Savio et al, 2014). Unsupervised classification was performed with cluster analysis (CA) to measure the similarity between samples (Kropf et al, 2010;Yudthavorasit, Wongravee, & Leepipatpiboon, 2014).…”
Section: Discussionmentioning
confidence: 99%
“…Significant difference between different sets of data from different regions was defined as p < 0.05 (Zhao et al, 2011(Zhao et al, , 2013. Principal component analysis (PCA) is a method for linear data analysis and is known for its capability to reduce the dimensionality of the data (Kropf et al, 2010;Savio et al, 2014). Unsupervised classification was performed with cluster analysis (CA) to measure the similarity between samples (Kropf et al, 2010;Yudthavorasit, Wongravee, & Leepipatpiboon, 2014).…”
Section: Discussionmentioning
confidence: 99%
“…Oils were prepared for ICP-MS using a method as described in Sabio (Savio et al, 2014). Approximately 500 mg of oils were weighed directly into microwave digestion vessels, followed by addition of nitric acid (5.0 mL).…”
Section: Metal Concentration Measurementmentioning
confidence: 99%
“…Furthermore, considering the techniques including graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled optical mass spectrometry (ICP-MS), inductively coupled optical atomic emission spectrometry (ICP-AES), high resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS), determination of the analyte can be achieved cheaper by this analytical procedure. The sensitivity of the suggested method can be found worse than some of the reports [4,17,18,19]. However, considering dilution of the sample, time consuming sample preparation step and high cost instrument requirement in these procedures, the presented method comes to the forefront.…”
Section: Discussionmentioning
confidence: 91%