2015
DOI: 10.1063/1.4914097
|View full text |Cite
|
Sign up to set email alerts
|

Multidimensional infrared spectroscopy reveals the vibrational and solvation dynamics of isoniazid

Abstract: The results of infrared spectroscopic investigations into the band assignments, vibrational relaxation, and solvation dynamics of the common anti-tuberculosis treatment Isoniazid (INH) are reported. INH is known to inhibit InhA, a 2-trans-enoyl-acyl carrier protein reductase enzyme responsible for the maintenance of cell walls in Mycobacterium tuberculosis but as new drug-resistant strains of the bacterium appear, next-generation therapeutics will be essential to combat the rise of the disease. Small molecules… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
6
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 70 publications
1
6
0
Order By: Relevance
“…The peak-to-peak amplitude of the chopped pump–probe signal from the 100 mM NMA- d is 20–30 mOD (50 μm path length, population time T 2 = 0.2 ps). This amplitude is comparable to, if not slightly larger than, that observed with 50 fs, 10 kHz and 100 fs, 1 kHz Ti:sapphire-based pump–probe setups. In both cases, these examples use 1.5–2 μJ of 6 μm mid-IR light generated from OPAs pumped with 500 μJ/pulse of 800 nm light.…”
Section: Resultssupporting
confidence: 77%
“…The peak-to-peak amplitude of the chopped pump–probe signal from the 100 mM NMA- d is 20–30 mOD (50 μm path length, population time T 2 = 0.2 ps). This amplitude is comparable to, if not slightly larger than, that observed with 50 fs, 10 kHz and 100 fs, 1 kHz Ti:sapphire-based pump–probe setups. In both cases, these examples use 1.5–2 μJ of 6 μm mid-IR light generated from OPAs pumped with 500 μJ/pulse of 800 nm light.…”
Section: Resultssupporting
confidence: 77%
“…FTIR measurements were carried out using a Bruker Vertex 70 spectrometer at a resolution of 1 cm –1 with sample concentrations of 2.5 mM (A 3 T 3 duplex/H-A 3 T 3 complex) or 5 mM ((AT) 3 duplex/H-(AT) 3 complex). 2D-IR spectra were collected using the ULTRA FT-2D-IR spectrometer. , The IR pulses used had a temporal duration of ∼100 fs, a center frequency of 1650 cm –1 , and a bandwidth of ∼300 cm –1 , at a repetition rate of 10 kHz. FT-2D-IR measurements were carried out at concentrations of 1.25 mM (A 3 T 3 duplex/H-A 3 T 3 complex) or 2.5 mM ((AT) 3 duplex/H-(AT) 3 complex).…”
Section: Methodsmentioning
confidence: 99%
“…Fourier Transform (FT)-IR absorption spectra were obtained using a Bruker Vertex 70v spectrometer with a resolution of 1 cm –1 and were the average of 20 coadded scans. 2D-IR spectra were acquired using the ULTRA laser system , via the FT-2D-IR method, reported previously, in which the mid-IR pulses were arranged in a pseudo pump–probe geometry. , The waiting time at which all spectra were acquired was 250 fs.…”
Section: Methods and Materialsmentioning
confidence: 99%