The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
1994
DOI: 10.1016/0003-2670(94)00090-5
|View full text |Cite
|
Sign up to set email alerts
|

Multicommutation in flow analysis. Part 1. Binary sampling: concepts, instrumentation and spectrophotometric determination of iron in plant digests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
81
0
28

Year Published

1997
1997
2017
2017

Publication Types

Select...
6
3

Relationship

5
4

Authors

Journals

citations
Cited by 313 publications
(118 citation statements)
references
References 10 publications
0
81
0
28
Order By: Relevance
“…The equipment set-up consisted of a home-made chemiluminescence detection unit based in the silicon photodiode (71608, Oriel instruments) coupled to a flow cell (78 μL inner volume) machined in acrylic; 22 a 586 microcomputer equipped with a PCL-711S electronic interface card (Advantech Corp); an IPC8 Ismatec peristaltic pump equipped with Tygon pumping tubes; a 12 V regulated power supply for the solenoid valves; a home-made electronic interface to match the voltage and current intensity required to drive the solenoid valves; 18 two mini-columns (10 mm length, 5 mm inner diameter) to pack the glass beads with immobilized enzyme; joint devices machined in acrylic; mixing coils and flow lines of polyethylene tubing (0.8 mm i.d. ); and accessories.…”
Section: Apparatusmentioning
confidence: 99%
See 1 more Smart Citation
“…The equipment set-up consisted of a home-made chemiluminescence detection unit based in the silicon photodiode (71608, Oriel instruments) coupled to a flow cell (78 μL inner volume) machined in acrylic; 22 a 586 microcomputer equipped with a PCL-711S electronic interface card (Advantech Corp); an IPC8 Ismatec peristaltic pump equipped with Tygon pumping tubes; a 12 V regulated power supply for the solenoid valves; a home-made electronic interface to match the voltage and current intensity required to drive the solenoid valves; 18 two mini-columns (10 mm length, 5 mm inner diameter) to pack the glass beads with immobilized enzyme; joint devices machined in acrylic; mixing coils and flow lines of polyethylene tubing (0.8 mm i.d. ); and accessories.…”
Section: Apparatusmentioning
confidence: 99%
“…This requisite could be easily achieved by implementing the analytical procedure in a flow system based on multicommutation process, which afforded ability to handle small volumes of sample and reagent solutions. 18 In this paper we intend to develop an automatic flow procedure based on multicommutation [19][20][21] for the determination of carbaryl in water. The procedure is based on the enzymatic reaction and detecting by chemiluminescence using an inexpensive instrument based on photodiode.…”
Section: Introductionmentioning
confidence: 99%
“…The set up was comprised of an IPC8 Ismatec peristaltic pump furnished with Tygon pumping tubes, six port and three-way solenoid valves (NResearch), a home made power supply interface 28 to match the electric current intensity and voltage required to drive the solenoid valves, a home-made Ag 2 S tubular electrode constructed as previously described, 29 a MicropH 2002 Crison potentiometer equipped with an Ag/AgCl reference electrode and a Pentium microcomputer equipped with a PCL-711S (Advantech) electronic interface card. The software to control the system was written in VisualBasic 3.0.…”
Section: Apparatus and Flow Set Upmentioning
confidence: 99%
“…However it reacts also with iron ions forming a compound which absorbs at the same wavelength range observed for the nickel compound, thus causing strong interference 4 . To overcome this drawback, a triethanolamine solution was used as masking reagent, added to the sample bulk during the sampling step, by employing the binary sampling approach 17 . Under this condition, the reaction coil (B1) is loaded with a string comprising slugs of sample in tandem with slugs of triethanolamine.…”
Section: Flow Diagrams and Flow Proceduresmentioning
confidence: 99%