2011
DOI: 10.1590/s0103-50532011000800017
|View full text |Cite
|
Sign up to set email alerts
|

Multiclass MSPD method for pesticide determination in dehydrated Hyptis pectinata (sambacaitá) medicinal plant by GC-MS

Abstract: Um método baseado na técnica de dispersão da matriz em fase sólida foi desenvolvido para determinar resíduos de ametrina, tetraconazol, flumetralina, tebuconazol, pirimetanil, diclofuanida e cresoxim-metílico na planta medicinal desidratada Hyptis pectinata (sambacaitá) por cromatografia a gás acoplada a espectrometria de massas. Diferentes parâmetros foram avaliados, tais como: tipo (C 18 , alumina neutra, sílica gel e Florisil) e quantidades de sorvente e solvente de eluição (diclorometano, acetato de etila … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
2
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 15 publications
0
2
0
1
Order By: Relevance
“…When comparing to chromatographic methods, our electrochemical method seems to be of similar sensitivity. Only some of chromatographic methods combined with mass spectrometry detection are more sensitive [ 11 , 12 ], while the others are less [ 6 , 8 , 9 , 13 ]. Quantification limit of our method is below the proposed MRL within European Union.…”
Section: Discussionmentioning
confidence: 99%
“…When comparing to chromatographic methods, our electrochemical method seems to be of similar sensitivity. Only some of chromatographic methods combined with mass spectrometry detection are more sensitive [ 11 , 12 ], while the others are less [ 6 , 8 , 9 , 13 ]. Quantification limit of our method is below the proposed MRL within European Union.…”
Section: Discussionmentioning
confidence: 99%
“…The application of field-developed biosensors depends directly on the obtained LODs, assessing whether they can detect low concentrations at trace levels of pesticide. Pesticide MRLs should always be considered in reliability studies of pesticide techniques [ 107 , 108 ]. As a result, the low readings were compared to the MLRs established by the Codex Alimentarius [ 109 ] and the United States Environmental Protection Agency (USEPA) [ 110 ].…”
Section: Dataset Visual Approachesmentioning
confidence: 99%
“…100,101 Dispersão da matriz em fase sólida Introduzida em 1989 por Barker e colaboradores, 102 a dispersão da matriz em fase sólida (matrix solid phase dispersion, MSPD) combina A natureza da coluna de MSPD e a faixa de interações torna a MSPD uma técnica apropriada para isolar e/ou limpar multirresíduo a partir de matrizes complexas. [102][103][104][105][106][107][108][109][110][111][112][113][114] O suporte sólido e o solvente de eluição são parâmetros críticos, mas esses certamente têm in fluência menor que a dispersão da matriz do topo até a base da coluna de MSPD. Na extração em fase sólida (solid phase extraction, SPE), a maioria das substâncias da amostra é retida nos primeiros milímetros do topo da coluna (efeito da matriz), enquanto que em MSPD a deposição da amostra com o sorvente na coluna é uniforme.…”
Section: Método Quechersunclassified