1982
DOI: 10.1063/1.1137176
|View full text |Cite
|
Sign up to set email alerts
|

Multichannel light detector system for visible continuum measurements on Alcator C

Abstract: A spatially resolving visible light detector system has been constructed and used to measure continuum radiation in the wavelength region near 5360 A on the Alcator C tokamak. The instrument measures the line integral brightnesses from 20 chords through the plasma. For high electron temperature regimes and relatively line-free wavelength regions, Zeff(r,t) is inferred from Abel inverted brightness profiles.During the steady-state portion of the discharge, Zeff(r) is usually found to be constant within 10% out … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
33
0
1

Year Published

1984
1984
2019
2019

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 58 publications
(34 citation statements)
references
References 4 publications
(3 reference statements)
0
33
0
1
Order By: Relevance
“…Thorough investigations of the plasma radiation spectra and of the atomic processes in the plasma in the vicinity of the density pedestal show that the measured visible continuum 6 emissivity is the free-free bremsstrahlung emissivity of the plasma [9]. Therefore, the only assumption not supported directly by experimental evidence, which is used when deriving the density profile, is the assumption of constant Z eff across the pedestal region.…”
Section: Pedestal Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thorough investigations of the plasma radiation spectra and of the atomic processes in the plasma in the vicinity of the density pedestal show that the measured visible continuum 6 emissivity is the free-free bremsstrahlung emissivity of the plasma [9]. Therefore, the only assumption not supported directly by experimental evidence, which is used when deriving the density profile, is the assumption of constant Z eff across the pedestal region.…”
Section: Pedestal Measurementsmentioning
confidence: 99%
“…Visible continuum profiles are measured with a 2048 element 1-D CCD array, which images emission from the plasma in a passband at 536±3 nm. The emission is dominated by free-free bremsstrahlung for T e > 20 eV [9] and therefore the electron density profile can be obtained from the emissivity measurements. The toroidal midplane views are abel-inverted to yield local emissivity profiles, with chordal resolution near the pedestal region of 2 mm, and time resolution of 4 ms. Soft x-ray emissivity is measured simultaneously at the top of the plasma and the outer midplane by photodiode arrays viewing the plasma edge region through 10 µm beryllium filters.…”
Section: Pedestal Measurementsmentioning
confidence: 99%
“…DOI: 10.21517/0202-3822-2017-40-3-14-22 ВВЕДЕНИЕ В составе оптических диагностик плазмы в современных термоядерных установках широко ис-пользуются кварцевые оптоволоконные коллекторы. Кварцевое оптоволокно имеет высокое свето-пропускание в видимом диапазоне спектра и позволяет передать свет из плазмы на детекторы в ди-агностической пультовой с хорошим пространственным разрешением и малыми потерями [1,2] . В большинстве случаев применяется оптоволокно типа кварц-кварц-полимер с сердцевиной из чис-того кварца и фторсодержащей наплавкой диаметром от 0,1 до 0,6 мм и с численной апертурой 0,22.…”
unclassified
“…A central line-averaged Z eff is routinely computed and is available online. The average Z eff is defined as (see [3])…”
Section: A Diagnostic For the Determination Of Z Eff On Textormentioning
confidence: 99%