Multicentre evaluation of the Tosoh HbA1c G8 analyser

Abstract: With respect to reproducibility, chromatographic resolution, speed of analysis and identification of Hb variants, the Tosoh G8 analyser can be considered to be state of the art.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
23
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 40 publications
(24 citation statements)
references
References 22 publications
0
23
0
1
Order By: Relevance
“…GHb levels were determined by the following five methods: HPLC method using ADAMS-A 1C HA-8160 (Arkray, Kyoto, Japan) 13 and that using HLC-723 G8 (Tosoh, Tokyo, Japan), 14 LA method (RAPIDIA Auto HbA 1C -L; Fujirebio, Tokyo, Japan), 15 enzymatic method (Nordia-N HbA 1C ; Sekisui Medical, Tokyo, Japan) 16 and affinity method (GHb V, affinity mode; Tosoh). 17,18 All these methods were corrected by using Japan Diabetes Society lot 2 GHb 19 and the normal control range of GHb for adults is from 4.3 to 5.3%.…”
Section: Discussionmentioning
confidence: 99%
“…GHb levels were determined by the following five methods: HPLC method using ADAMS-A 1C HA-8160 (Arkray, Kyoto, Japan) 13 and that using HLC-723 G8 (Tosoh, Tokyo, Japan), 14 LA method (RAPIDIA Auto HbA 1C -L; Fujirebio, Tokyo, Japan), 15 enzymatic method (Nordia-N HbA 1C ; Sekisui Medical, Tokyo, Japan) 16 and affinity method (GHb V, affinity mode; Tosoh). 17,18 All these methods were corrected by using Japan Diabetes Society lot 2 GHb 19 and the normal control range of GHb for adults is from 4.3 to 5.3%.…”
Section: Discussionmentioning
confidence: 99%
“…At baseline and after 10 weeks of treatment, blood samples were collected at the outpatient clinic in the morning after overnight fasting for measurement of the following parameters: HbA 1c , 1,5-anhydro-D-glucitol (1,5-AG), glucose, insulin, glucagon, non-esterified fatty acid (NEFA), total cholesterol, TG, high-density lipoprotein cholesterol, apolipoprotein AI, apolipoprotein AII, apolipoprotein B (ApoB), apolipoprotein CII, apolipoprotein CIII, apolipoprotein E, apolipoprotein B48 (ApoB-48), remnantlike particle cholesterol (RLP-C), aspartate aminotransferase, alanine aminotransferase, and creatinine. A high-performance liquid chromatography (HLC-723 G8; Tosoh, Tokyo, Japan) system was used to measure HbA 1c according to the International Federation of Clinical Chemistry reference standard methods [12], and HbA 1c values are therefore shown as National Glycohemoglobin Standardization Program equivalent values in this study. 1,5-AG levels were measured using the enzymatic method with the "Lana AG" column-enzyme assay kit (Nippon Kayaku Co. Ltd., Tokyo, Japan) [13].…”
Section: Measurementsmentioning
confidence: 99%
“…Many new devices introduced on the market using different principles of HbA 1c measurement were scientifically evaluated: HPLC [134,135] , immunoassay [136] , enzymatic assay [137] and even capillary electrophoresis [138] which was previously considered unsuitable for routine HbA 1c assay [139] . Most of these methods showed improved performances in terms of precision and specificity.…”
Section: The Times Of Expansionmentioning
confidence: 99%