2009
DOI: 10.1002/jmri.21781
|View full text |Cite
|
Sign up to set email alerts
|

Multicenter validation of the magnetic resonance t2* technique for segmental and global quantification of myocardial iron

Abstract: Purpose:To assess the transferability of the magnetic resonance imaging (MRI) multislice multiecho T2* technique for global and segmental measurement of iron overload in thalassemia patients. Materials and Methods:Multiecho T2* sequences were installed on six MRI scanners. Five healthy subjects (n ϭ 30) were scanned at each site; five thalassemia major (TM) patients were scanned at the reference site and were rescanned locally (n ϭ 25) within 1 month. T2* images were analyzed using previously validated softwar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

4
87
0
1

Year Published

2010
2010
2023
2023

Publication Types

Select...
6
2

Relationship

3
5

Authors

Journals

citations
Cited by 115 publications
(92 citation statements)
references
References 21 publications
4
87
0
1
Order By: Relevance
“…5 All centers are linked by a web-based network, configured to collect and share the patients' history, clinical and diagnostic data. 6 At all six sites, cardiac MRI examinations were performed using 1.5 T scanners.…”
Section: Design and Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…5 All centers are linked by a web-based network, configured to collect and share the patients' history, clinical and diagnostic data. 6 At all six sites, cardiac MRI examinations were performed using 1.5 T scanners.…”
Section: Design and Methodsmentioning
confidence: 99%
“…11,12 The intraobserver, inter-observer and inter-study variabilities of the proposed methodology have been previously assessed. 5,7 The transferability of multislice multiecho T2* within the MIOT network has been previously validated. 5 Steady-state free procession cine images were acquired to assess ventricular function parameters (left ventricular volumes, mass and ejection fraction) quantitatively in a standard way.…”
Section: Design and Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Inter-site reproducibility within the network was previously assessed (18). MRI was performed using a 1.5 Tesla (T) MRI scanner (GE Signa/Excite HD, Milwaukee, WI).…”
Section: Mri Acquisition and Image Analysismentioning
confidence: 99%
“…We analyzed 434 Thalassemia Major (TM) patients (233 males, mean age 31 ± 9 years) consecutively enrolled in the MIOT (Myocardial Iron Overload in Thalassemia) study [1]. CMR was performed using a 1.5 T MR scanner (GE Signa/Excite).…”
Section: Methodsmentioning
confidence: 99%