Through a detailed analysis of the construction of HT-7. a decoupling model for heating field and vertical field is given. This paper presents a simple introduction of its basic structure. And with a practical design, this model has been successfully applied to the device, procuring a very good controlling of the plasma parameters of HT-7. The performance of individual feedback systems is also analyzed in detail.