2012
DOI: 10.1364/ao.51.002624
|View full text |Cite
|
Sign up to set email alerts
|

Multi-spatial-frequency and phase-shifting profilometry using a liquid crystal phase modulator

Abstract: Optical profilometry is widely applied for measuring the morphology of objects by projecting predetermined patterns on them. In this technique, the compact size is one of the interesting issues for practical applications. The generation of pattern by the interference of coherent light sources has a potential to reduce the dimension of the illumination part. Moreover, this method can make fine patterns without projection optics, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
13
0
1

Year Published

2013
2013
2023
2023

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 13 publications
(14 citation statements)
references
References 19 publications
0
13
0
1
Order By: Relevance
“…In this manner, the whole scanning time required for the four-step multi-spatial frequencies and four-step phase shifting schemes could be completed in less than 800 ms. This means that the optical surface profilometry can capture 16 sets of fringe patterns distorted by an object in less than 800 ms. Our profilometry using the DFPG can exhibit quite fast scanning and capturing speeds suitable for hand-held dental applications, compared with our previous study of a 3D optical surface profilometry system constructed with a mechanically moving optical element [21]. …”
Section: Operation Principle Of the Dfpg And The Theory Of Depth Ementioning
confidence: 99%
See 3 more Smart Citations
“…In this manner, the whole scanning time required for the four-step multi-spatial frequencies and four-step phase shifting schemes could be completed in less than 800 ms. This means that the optical surface profilometry can capture 16 sets of fringe patterns distorted by an object in less than 800 ms. Our profilometry using the DFPG can exhibit quite fast scanning and capturing speeds suitable for hand-held dental applications, compared with our previous study of a 3D optical surface profilometry system constructed with a mechanically moving optical element [21]. …”
Section: Operation Principle Of the Dfpg And The Theory Of Depth Ementioning
confidence: 99%
“…The fringe visibility of the dynamic fringe patterns was about 0.9 in our system. This fringe visibility was enough to obtain the 3D depth extraction with our four-step phase-shifting and four steps of multi-spatial frequency scheme [21]. The beam from the He-Ne laser was expanded by a beam expander and was passed through an iris to reduce the optical noise so that a suitable spot size with a uniform beam intensity can cover all of the five Al slits.…”
Section: Operation Principle Of the Dfpg And The Theory Of Depth Ementioning
confidence: 99%
See 2 more Smart Citations
“…이 방법에서 얻은 위상 정보는 0에서 2π로 한정되어 있기 때문에 일반적으로 unwrapping 알고리즘을 사용해야 올 바른 깊이 정보를 추출할 수 있다. 하지만 다중 공간 주파수 를 이용하여 각각의 주파수에 대하여 위상 천이 기술을 적용 할 경우 unwrapping 알고리즘을 적용하지 않고 깊이 정보를 계산할 수 있어서 unwrapping 알고리즘의 오류로 인하여 오 차가 발생하는 것을 피할 수 있다 [13,14] …”
unclassified