Abstract: The development and validation of a system for multi-site photoplethysmography (PPG) and electrocardiography (ECG) is presented. The system could acquire signals from 8 PPG probes and 10 ECG leads. Each PPG probe was constituted of a light-emitting diode (LED) source at a wavelength of 940 nm and a silicon photomultiplier (SiPM) detector, located in a back-reflection recording configuration. In order to ensure proper optode-to-skin coupling, the probe was equipped with insufflating cuffs. The high number of PP… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
18
0
1

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 20 publications
(19 citation statements)
references
References 39 publications
0
18
0
1
Order By: Relevance
“…Photoplethysmographic data were acquired with a home-made multi-channel system [34][35][36] ( Figure 2a) equipped with 7 PPG probes. Each probe was composed of a light emitting diode at 940 nm of wavelength (SMC940 LED, Roithner Laser Technik, Vienna, Austria) and a photodetector based on large area n-on-p silicon photomultiplier (SiPM) [37,38] produced at STMicroelectronics (Catania, Italy).…”
Section: Photoplethysmographic (Ppg) and Electrocardiographic (Ecg) Rmentioning
confidence: 99%
“…Photoplethysmographic data were acquired with a home-made multi-channel system [34][35][36] ( Figure 2a) equipped with 7 PPG probes. Each probe was composed of a light emitting diode at 940 nm of wavelength (SMC940 LED, Roithner Laser Technik, Vienna, Austria) and a photodetector based on large area n-on-p silicon photomultiplier (SiPM) [37,38] produced at STMicroelectronics (Catania, Italy).…”
Section: Photoplethysmographic (Ppg) and Electrocardiographic (Ecg) Rmentioning
confidence: 99%
“…As shown in the figure, during the ECW epochs, the calculated spectral entropy values were within the defined thresholds. It should be noted here that the developed system was validated based on visual inspection of the PPG signal, however, further validation studies are necessary to compare our system with a gold standard such as ECG [ 8 , 49 ].…”
Section: Resultsmentioning
confidence: 99%
“…Sensors 2020, 20, x FOR PEER REVIEW 14 of 17 the developed system was validated based on visual inspection of the PPG signal, however, further validation studies are necessary to compare our system with a gold standard such as ECG [8,49].…”
Section: Real-time Heart Rate Monitoring Algorithmmentioning
confidence: 99%
“…The proposed system for monitoring the JVP waveform is a viable alternative to the non-invasive methodologies that are currently under investigation but that still require the presence of a qualified healthcare operator to be carried out, such as using a photoplethysmography imaging system or a microwave sensor, or alternatively via force-coupled single crystal ultrasound [ 33 , 34 , 35 , 36 , 37 ]. Between these methodologies, the photoplethysmography system has seen the greatest advancement in this field by combining multi-site acquisition techniques and machine learning approaches to improve reliability and effectiveness in the assessment of cardiovascular risk [ 38 , 39 ].…”
Section: Discussionmentioning
confidence: 99%