Multi-site harmonization of 7 tesla MRI neuroimaging protocols

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
43
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
3

Relationship

4
5

Authors

Journals

citations
Cited by 42 publications
(46 citation statements)
references
References 37 publications
0
43
0
Order By: Relevance
“…B 1 + -calibration was performed initially using the vendor's default adjustment scans. A 3D DREAM sequence ( Nehrke and Bornert, 2012 ; Ehses et al., 2019 ) was subsequently acquired and the transmit voltage (or power attenuation) was then adjusted for all subsequent imaging based on the mean flip-angle from the brain in an anatomically-specified axial slice of the 3D DREAM flip angle map as described in Clarke et al. (2019) .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…B 1 + -calibration was performed initially using the vendor's default adjustment scans. A 3D DREAM sequence ( Nehrke and Bornert, 2012 ; Ehses et al., 2019 ) was subsequently acquired and the transmit voltage (or power attenuation) was then adjusted for all subsequent imaging based on the mean flip-angle from the brain in an anatomically-specified axial slice of the 3D DREAM flip angle map as described in Clarke et al. (2019) .…”
Section: Methodsmentioning
confidence: 99%
“…Multi-echo 1.4mm isotropic resolution T 2 *-weighted GE data were acquired with: TE 1 /TR=4/43ms; 8 echoes with monopolar gradient readouts; echo-spacing=5ms; FA=15°; bandwidth=260Hz/px; acceleration-factor=4 (Sites-1/2/4/5) or 2 × 1.5 (Site-3); FOV=269 × 218 × 157mm 3 ; scan-time ~6min (Sites-1/2/4/5) and ~4 min (Site-3). For Siemens data, coil combination was performed using a custom implementation of Roemer's algorithm, as previously described ( Clarke et al., 2019 ). Subject 6’s single-echo scan failed to reconstruct using Roemer's method on data from the first visit at Site-5 so a sum-of-squares (SoS) algorithm was used for coil combination for that scan instead.…”
Section: Methodsmentioning
confidence: 99%
“…A high resolution isotropic T1-w MP2RAGE image was also acquired sagittally for anatomical coregistration using the UK7T Network harmonised protocol (Clarke et al, 2019): TR = 3500 ms, TE = 2.58 ms, BW = 300 Hz/px, voxel size = 0.7 x 0.7 x 0.7 mm, FoV = 224 x 224 x 157 mm, acceleration factor (A>>P) = 3, flip angles = 5/2° and inversion times (TI) = 725/2150 ms for the first/second images. The total acquisition time of the MP2RAGE was 7 minutes and 51 seconds.…”
Section: Methodsmentioning
confidence: 99%
“…Quality assessment, standardization and harmonization of 7T MRI protocols are increasingly becoming appreciated by the neuroimaging field to allow utilization and generalization of protocols across studies, imaging sites and scanner vendors (Poldrack et al, 2017). Several nationwide (Clarke et al, 2019;Voelker et al, 2016) and international (Düzel et al, 2019) initiatives have embarked on such establishments indicating the importance of this issue. These consortia aim to set up standardized sequences across the main 7T MRI vendors to limit the long-known effects of hard-(e.g.…”
Section: Introductionmentioning
confidence: 99%