2022
DOI: 10.1016/j.enconman.2021.115136
|View full text |Cite
|
Sign up to set email alerts
|

Multi-objective optimization of a solar-driven polygeneration system based on CO2 working fluid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1
1

Relationship

1
9

Authors

Journals

citations
Cited by 28 publications
(5 citation statements)
references
References 44 publications
0
4
0
Order By: Relevance
“…An ORC driven by flat plate solar collectors tested by Pinerez et al 20 gives a maximum efficiency of 14.6%. Tzivanidis et al 21 used ORC with equivalent solar collectors and they concluded that an investment payback period is close to nine years and the annual system efficiency is 15.1%, these results agree with the experimental data of Georgousis et al 22 Guangli et al 23 have tested a two-stage ORC that is being proposed for the recovery and utilization of low-grade heat from single flash geothermal power plant exhaust flue fluids using working fluids R227ea and R116. The results show that [24][25][26][27][28][29] the thermal efficiency and amount of electricity produced by a solar ORC system can be increased by lowering the condensing temperature.that work with different solar collectors.…”
Section: Tionsupporting
confidence: 55%
“…An ORC driven by flat plate solar collectors tested by Pinerez et al 20 gives a maximum efficiency of 14.6%. Tzivanidis et al 21 used ORC with equivalent solar collectors and they concluded that an investment payback period is close to nine years and the annual system efficiency is 15.1%, these results agree with the experimental data of Georgousis et al 22 Guangli et al 23 have tested a two-stage ORC that is being proposed for the recovery and utilization of low-grade heat from single flash geothermal power plant exhaust flue fluids using working fluids R227ea and R116. The results show that [24][25][26][27][28][29] the thermal efficiency and amount of electricity produced by a solar ORC system can be increased by lowering the condensing temperature.that work with different solar collectors.…”
Section: Tionsupporting
confidence: 55%
“…An assumption of this work is the selection of the solar field area at 300 m 2 and the storage tank at 5 m 3 . Moreover, It is critical to say that the thermodynamic model for simple ORC has been validated in our previous works [28]. However, it is important to again provide validation evidence in order to be clear about the accuracy of the developed model.…”
Section: Simulation Of the Developed Modelsmentioning
confidence: 99%
“…The solar system is designed based on the location of Jazan city, KSA, and all-weather information of the temperatures. And to obtain the highest thermal energy, the values of the temperature between 150 o C to 240 o C were used from 8 am to 17 pm, and the working hours vary according to the year seasons [57][58][59][60][61][62][63][64][65][66][67]. According to the results of some researchers [18,34,58,[68][69][70][71][72], at an air temperature of 35, the system gives a heat concentration of up to 403 degrees Celsius, produced by one equivalent dish, equivalent to 4576 watts.…”
Section: Components and Alternative Of Orc Working Fluidsmentioning
confidence: 99%