2010
DOI: 10.1117/12.844531
|View full text |Cite
|
Sign up to set email alerts
|

Multi-material decomposition of spectral CT images

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
28
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 39 publications
(29 citation statements)
references
References 0 publications
1
28
0
Order By: Relevance
“…The work in [23] applies different models for the density of a mixture to derive a constraint that allows triple material decomposition prior to image reconstruction. Finally, of special interest is [24], which explores pre-reconstruction concepts first introduced in a preliminary version of the present work [25]. Although pre-reconstruction methods lack the flexibility and computational efficiency of our technique, they are potentially more accurate.…”
Section: A Related Workmentioning
confidence: 97%
See 2 more Smart Citations
“…The work in [23] applies different models for the density of a mixture to derive a constraint that allows triple material decomposition prior to image reconstruction. Finally, of special interest is [24], which explores pre-reconstruction concepts first introduced in a preliminary version of the present work [25]. Although pre-reconstruction methods lack the flexibility and computational efficiency of our technique, they are potentially more accurate.…”
Section: A Related Workmentioning
confidence: 97%
“…This model allows for the establishment of a relationship between and , because the introduction of the linear constraint in (1) immediately allows for decompositions into material triplets rather than a material pair [25]. Since and are related via , the derivation of such correlation requires a model for .…”
Section: Multi-materials Decompositionmentioning
confidence: 99%
See 1 more Smart Citation
“…Future studies may determine the accuracy of contrast medium quantification and whether dual-energy CT or spectral CT may provide reliable images of more than two contrast media (17).…”
Section: Technical Developmentsmentioning
confidence: 99%
“…By contrast, virtual unenhanced images generated by dual-energy CT scanners with fast kilovoltage switching provide lesion density measurements in milligrams per milliliter of water and do not allow attenuation measurements; although image processing algorithms exist that would allow the extrapolation of attenuation data in Hounsfield units from these images, scanners with such algorithms are not yet available for clinical use (29).…”
Section: Renal Mass Characterizationmentioning
confidence: 91%