2020
DOI: 10.1016/j.jelectrocard.2019.11.039
|View full text |Cite
|
Sign up to set email alerts
|

Multi-electrode mapping of complex macroreentry atrial tachycardia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
7
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…18 In another study compared conventional activation mapping performed by Thermocool using the Carto 3 system with MEM in scar-related ATs, MEM showed a shorter procedure duration and mapping duration with more mapping points, and lower recurrence risk of ATs post ablation. 1 The more recent 64-pole basket mapping catheter (IntellaMap Orion TM, Boston Scientific), which incorporates very small flat (0.4 mm 2 ; 2.5 mm spacing) and unidirectional electrodes, further improved these aspects. 20,21 Maps produced experimentally with the Rhythmia mapping system using this catheter had an unprecedented electrogram resolution (2.6 mm), the noise was very low (< 0.01 mV) and were highly accurate, without need for manual reannotation.…”
Section: Escalating Multielectrode Mapping Cathetersmentioning
confidence: 99%
See 4 more Smart Citations
“…18 In another study compared conventional activation mapping performed by Thermocool using the Carto 3 system with MEM in scar-related ATs, MEM showed a shorter procedure duration and mapping duration with more mapping points, and lower recurrence risk of ATs post ablation. 1 The more recent 64-pole basket mapping catheter (IntellaMap Orion TM, Boston Scientific), which incorporates very small flat (0.4 mm 2 ; 2.5 mm spacing) and unidirectional electrodes, further improved these aspects. 20,21 Maps produced experimentally with the Rhythmia mapping system using this catheter had an unprecedented electrogram resolution (2.6 mm), the noise was very low (< 0.01 mV) and were highly accurate, without need for manual reannotation.…”
Section: Escalating Multielectrode Mapping Cathetersmentioning
confidence: 99%
“…These scar‐related ATs are difficult to manage medically and frequently recur after electrical cardioversion 4 . The success of catheter ablation is decided by the precise diagnosis of the AT mechanism, which is challenging as a result of underlying cardiac disease and iatrogenic lesion sets with a resultant complex atrial substrate 1–3,5 . High‐density mapping (HDM) technologies have enabled rigorous elucidation of atrial arrhythmia mechanisms in patients post cardiac surgery 6 .…”
Section: Introductionmentioning
confidence: 99%
See 3 more Smart Citations