2006
DOI: 10.1002/pd.1486
|View full text |Cite
|
Sign up to set email alerts
|

Multi‐centre first‐trimester screening for Down syndrome in the Netherlands in routine clinical practice

Abstract: Objectives This is the first report on the results of a first‐trimester combined‐test screening programme in the Netherlands in a multi‐centre routine clinical setting. Methods Between July 2002 and May 2004, blood samples were taken from subjects in 44 centres in the Netherlands and sent to our laboratory to assay for maternal serum concentrations of fβ‐hCG and PAPP‐A. Fetal nuchal translucency (NT) was measured in the participating centres at a gestational age (GA) of 10–14 weeks. Results of those pregnancie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
16
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 36 publications
2
16
0
Order By: Relevance
“…For Dutch operators, the latter curve seemed to give a more accurate estimate of expected medians. Over the period July 2002 to May 2004 a mean median NT‐MoM of 0.83, based on the reference curve of Nicolaides et al , was described8. In the current study, the median NT‐MoM increased over time (Figure 2) and was 0.96 at the end of 2006.…”
Section: Discussionsupporting
confidence: 65%
See 1 more Smart Citation
“…For Dutch operators, the latter curve seemed to give a more accurate estimate of expected medians. Over the period July 2002 to May 2004 a mean median NT‐MoM of 0.83, based on the reference curve of Nicolaides et al , was described8. In the current study, the median NT‐MoM increased over time (Figure 2) and was 0.96 at the end of 2006.…”
Section: Discussionsupporting
confidence: 65%
“…Two types of quality assurance can be distinguished, both of which have been applied to the measurement of NT7–9. With qualitative assurance, aspects which contribute to adequate NT measurement, for example a correct sectional plane view of the fetus or caliper placement, are evaluated through the submission of ultrasound prints by the operator to an examining body; based on scores given by experts the quality of NT measurements can be determined10.…”
Section: Introductionmentioning
confidence: 99%
“…This setting differs from most other reports on this topic, in that the NT measurements are being performed as part of routine practice and not as part of a research protocol. 5,6,16,17 Given the widely varying characteristics of our participating laboratories, the findings are likely to be representative of current practice in North America. Overall, 39% of the screened women had NT measured by a sonographer who submitted too few samples to that laboratory for adequate and timely quality assurance monitoring.…”
Section: Discussionmentioning
confidence: 95%
“…For this retrospective dataset information on the pregnancy outcomes (e.g., child ' s birth date, birth weight and chromosomal abnormalities) was available (collected through self-reporting of the pregnant women, with a 70 % recall rate and considered to be an unbiased representation of the study population -see [9] -with a slight coincidental overrepresentation of missed Down syndrome cases). Serum concentrations of PAPP-A and f β -hCG were entered into the Astraia software to calculate MoMs and risks (calculations kindly provided with the help of Dr. R.J.M.…”
Section: Pre-harmonizationmentioning
confidence: 99%
“…The reported gestational age was based on the fi rst day of the last menstrual period (LMP) or on the fetal crown-rump length (CRL) [9] .…”
Section: Logistics Of the Fi Rst Trimester Combined Testmentioning
confidence: 99%