2004
DOI: 10.1007/s00134-004-2235-3
|View full text |Cite
|
Sign up to set email alerts
|

Mucociliary function deteriorates in the clinical range of inspired air temperature and humidity

Abstract: Objective: To test whether a reduction in air temperature within the clinical range [37 C to 30, 100% relative humidity (RH)] altered mucus transport velocity (MTV) and ciliary beat frequency (CBF) in an in vitro ovine tracheal model. Design: Controlled laboratory study. Setting: University research laboratory. Subjects: Farm-reared sheep. Interventions: Tracheae were mounted flat in an organ bath. Krebs Henseleit bathed the serosal surface and air at 100% (RH) was passed over the mucosal surface at 4 l/min.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
115
1
1

Year Published

2006
2006
2022
2022

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 117 publications
(119 citation statements)
references
References 10 publications
2
115
1
1
Order By: Relevance
“…9 This preparation had several advantages over using the trachea as a tube. Reducing the distance over which the mucus is timed allows measurement of mucus-transport velocity over a few seconds.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…9 This preparation had several advantages over using the trachea as a tube. Reducing the distance over which the mucus is timed allows measurement of mucus-transport velocity over a few seconds.…”
Section: Discussionmentioning
confidence: 99%
“…9 We cut a sheep trachea lengthwise along the ventral midline, opened it, and, with minimal stretching, mounted it with pins over the bathing fluid container. It was held in place with a poly-methyl-methacrylate top that fit over the pins.…”
Section: Flat-mounted Trachea Preparationmentioning
confidence: 99%
See 1 more Smart Citation
“…45,46 Care should be taken to quickly provide humidification to patients with artificial airways. Active humidifiers capable of quick warm-up and self-regulation (temperature and water levels) that require few disruptions offer many advantages.…”
Section: Airway Maintenance Humidificationmentioning
confidence: 99%
“…This reduction proceeded quickly to complete cessation. Complete cessation occurred much quicker at a temperature of 30°C, 46 in which most heat-and-moisture exchangers (HMEs) perform. Proper heating and humidification of inspiratory gas keeps the mucociliary ladder moving at a natural pace.…”
Section: Airway Maintenance Humidificationmentioning
confidence: 99%