2010
DOI: 10.1016/j.jocn.2010.01.016
|View full text |Cite
|
Sign up to set email alerts
|

MRI safety; nephrogenic systemic fibrosis and other risks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
23
0
8

Year Published

2010
2010
2015
2015

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(31 citation statements)
references
References 114 publications
0
23
0
8
Order By: Relevance
“…This compares favourably to the incidence with iodinated contrast media used with CT (0.03%–0.16%) 29. Patients with a pre-existing allergy to other contrast agents (such as iodine) may confer a greater risk of anaphylaxis to gadolium-based contrast agents, thus highlighting the need for a thorough screening questionnaire prior to any contrast administration 23 25…”
Section: Finally a Word On Safetymentioning
confidence: 99%
See 1 more Smart Citation
“…This compares favourably to the incidence with iodinated contrast media used with CT (0.03%–0.16%) 29. Patients with a pre-existing allergy to other contrast agents (such as iodine) may confer a greater risk of anaphylaxis to gadolium-based contrast agents, thus highlighting the need for a thorough screening questionnaire prior to any contrast administration 23 25…”
Section: Finally a Word On Safetymentioning
confidence: 99%
“…Painful and pruritic, plaque-like ‘woody’ induration of the skin occurs later in the course of the disease with the legs more commonly affected than the arms and torso. The face is spared 25. These cutaneous manifestations may lead to contractures and limit mobility.…”
Section: Finally a Word On Safetymentioning
confidence: 99%
“…The high incidence of renal compromise in VHL patients from RCC and renal cysts frequently precludes the use of gadolinium-based contrast due to the risk of nephrogenic systemic sclerosis. 28 The typical MRI appearance of a CNS haemangioblastoma is of a brightly enhancing mass, clearly delineated from the surrounding brain or spinal cord. The tumour tissue may be hypointense or isointense on precontrast T1-weighted MRI and hyperintense on T2-weighted MRI.…”
Section: Diagnosis and Typical Imaging Featuresmentioning
confidence: 99%
“…Various resources publish MRI compatibility for individual devices, allowing for verification of safety prior to image acquisition, including the Institute for Magnetic Resonance Imaging Safety, Education and Research website [102]. Of the more than 2300 devices tested on the website, over 900 have been certified at 3T or higher field strength [15]. While promising, the possibility exists that a device that is 'weakly' ferromagnetic at 1.5T will have significant interaction with a high strength magnetic field such as 3T [16].…”
Section: Safetymentioning
confidence: 99%