2007
DOI: 10.1055/s-2007-963607
|View full text |Cite
|
Sign up to set email alerts
|

MRI of the Knee at 7.0 Tesla

Abstract: Gradient echo sequences provide excellent image contrast at very high spatial resolution in a reasonable scan time. However, not all sequences used at 1.5 T are currently well suited for high-field imaging, in particular SAR-intensive sequences. Imaging of meniscal tears and lesions of the cruciate ligaments may benefit from the higher spatial resolution. The most favorable clinical indication for knee examinations at 7 T currently appears to be cartilage imaging.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

1
25
0
2

Year Published

2008
2008
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(28 citation statements)
references
References 0 publications
1
25
0
2
Order By: Relevance
“…Reasons for the long examination time were the long scanning time itself that was partly due to little experience with the scanning protocols and the optimization of image contrasts as well as a lack of routine with subjects' logistics (e.g., handling of the coils, manual movement of the scanner table). However, working routine and the establishment of standardized protocols will bring a significant reduction in examination time [Kraff et al, 2007]; although the length of a 7 T examination might, in general, be longer than for 1.5 T given that higher spatial resolutions are usually desired and achievable.…”
Section: Discussionmentioning
confidence: 99%
“…Reasons for the long examination time were the long scanning time itself that was partly due to little experience with the scanning protocols and the optimization of image contrasts as well as a lack of routine with subjects' logistics (e.g., handling of the coils, manual movement of the scanner table). However, working routine and the establishment of standardized protocols will bring a significant reduction in examination time [Kraff et al, 2007]; although the length of a 7 T examination might, in general, be longer than for 1.5 T given that higher spatial resolutions are usually desired and achievable.…”
Section: Discussionmentioning
confidence: 99%
“…Different field strengths are used for MRI, commonly ranging from 0.2 to 4.0 Tesla (T). Higher field strengths have been scientifically introduced with up to 7.0 T and more since 2007 (5).…”
mentioning
confidence: 99%
“…As MSK MRI involves imaging of stationary tissue without the need for breath-holding, potentially advantageous characteristics of high-field MRI could be exploited to their full extent. This results in excellent visualization of detailed anatomy [42,43] Fig. 4) and reveals its superiority compared to lower, yet well-established field strengths (3 T) [44,45].…”
mentioning
confidence: 99%