2014
DOI: 10.1002/jmri.24717
|View full text |Cite
|
Sign up to set email alerts
|

MR system operator: Recommended minimum requirements for performing MRI in human subjects in a research setting

Abstract: on behalf of the ISMRM Safety CommitteeThis article is intended to provide guidelines for the minimum level of safety and operational knowledge that an MR system operator should exhibit in order to safely perform an MR procedure in a human subject in a research setting. This article represents the position of the International Society for Magnetic Resonance in Medicine (ISMRM) regarding this important topic and was developed by members of this society's MR Safety Committee. DESCRIPTIONTHE CONTENT of this arti… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(6 citation statements)
references
References 1 publication
0
6
0
Order By: Relevance
“…Safety considerations are discussed under the headings related to: establishing, implementing, and maintaining current MR safety policies and procedures; static magnetic field issues; safety screening; staffing; pregnancy; paediatrics; time varying gradient magnetic field; time varying radiofrequency field; cryogen-related issues; claustrophobia, anxiety, sedation, and anaesthesia; contrast agents; and implants. Similarly, the International Society of Magnetic Resonance in Medicine (ISMRM) have published guidance related to the safe use of MRI for research purposes where they discuss: roles and responsibilities; minimum qualification requirements; operating modes; and considerations for the patient/research subject [33].…”
Section: Mri Safetymentioning
confidence: 99%
“…Safety considerations are discussed under the headings related to: establishing, implementing, and maintaining current MR safety policies and procedures; static magnetic field issues; safety screening; staffing; pregnancy; paediatrics; time varying gradient magnetic field; time varying radiofrequency field; cryogen-related issues; claustrophobia, anxiety, sedation, and anaesthesia; contrast agents; and implants. Similarly, the International Society of Magnetic Resonance in Medicine (ISMRM) have published guidance related to the safe use of MRI for research purposes where they discuss: roles and responsibilities; minimum qualification requirements; operating modes; and considerations for the patient/research subject [33].…”
Section: Mri Safetymentioning
confidence: 99%
“…However, the more people who check the MR safety, the better it will be. International guidelines state that to be able to handle emergencies and to maintain MR safety at the site, there should be two staff members at a site with a single scanner [ 10 , 14 , 22 ] and at least three staff members in a dual scanner unit.…”
Section: Discussionmentioning
confidence: 99%
“…PET/MRI is essentially a new modality, and it is relevant to consider the type of personnel involved in a facility that combines PET and MRI, most notably because of the unique radiation and MRI safety considerations (2,12,13). The requirements for an MRI facility are based on staff and patient restrictions through MRI safety education.…”
Section: Staffing Factorsmentioning
confidence: 99%