2019
DOI: 10.3390/nano9101466
|View full text |Cite
|
Sign up to set email alerts
|

MPI Phantom Study with A High-Performing Multicore Tracer Made by Coprecipitation

Abstract: Magnetic particle imaging (MPI) is a new imaging technique that detects the spatial distribution of magnetic nanoparticles (MNP) with the option of high temporal resolution. MPI relies on particular MNP as tracers with tailored characteristics for improvement of sensitivity and image resolution. For this reason, we developed optimized multicore particles (MCP 3) made by coprecipitation via synthesis of green rust and subsequent oxidation to iron oxide cores consisting of a magnetite/maghemite mixed phase. MCP … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
22
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 17 publications
(23 citation statements)
references
References 55 publications
1
22
0
Order By: Relevance
“…Images of IVC reconstructed at the time of peak of bolus or nearly after (t 1 ) showed similar adequate image quality (Supplement S1) except for Resovist at dosage of 0.025 mmol Fe/Kg, where the IVC image provided adequate image quality only at time of peak of bolus. The contributing factors in the image quality in images of MCP 3 in comparison to Resovist are the higher signal amplitude and slower drop of higher harmonics (Supplement S2) 14 .…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Images of IVC reconstructed at the time of peak of bolus or nearly after (t 1 ) showed similar adequate image quality (Supplement S1) except for Resovist at dosage of 0.025 mmol Fe/Kg, where the IVC image provided adequate image quality only at time of peak of bolus. The contributing factors in the image quality in images of MCP 3 in comparison to Resovist are the higher signal amplitude and slower drop of higher harmonics (Supplement S2) 14 .…”
Section: Resultsmentioning
confidence: 99%
“…Similar to conventional www.nature.com/scientificreports/ CT-angiography, variations in reconstruction parameters can alter the D L measurement. Standardized set of reconstruction parameters, based on previous phantom studies 14 were applied for all examinations to maintain results comparable and reliable. Nevertheless, the obtained values of AA D L and IVC D L are in good agreement with the literature 25 .…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations