2014
DOI: 10.1161/hypertensionaha.113.02885
|View full text |Cite
|
Sign up to set email alerts
|

Moving On—On Average in the Right Direction?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 16 publications
(5 citation statements)
references
References 12 publications
0
5
0
Order By: Relevance
“…20,23,25,26,28 The brachial blood pressure, used in daily practice, underestimate real invasive brachial pressure. The same holds true for all devices that are 37 Estimation methods have been improved, devices now calibrate their central pressures estimation using mean and diastolic pressure instead of systolic brachial blood pressure, since these appear to be constant, whereas systolic pressure varies along the arterial tree. Since in our study the same method was used before and after treatment, the same errors occurred at the two measurements.…”
Section: Discussionmentioning
confidence: 89%
See 3 more Smart Citations
“…20,23,25,26,28 The brachial blood pressure, used in daily practice, underestimate real invasive brachial pressure. The same holds true for all devices that are 37 Estimation methods have been improved, devices now calibrate their central pressures estimation using mean and diastolic pressure instead of systolic brachial blood pressure, since these appear to be constant, whereas systolic pressure varies along the arterial tree. Since in our study the same method was used before and after treatment, the same errors occurred at the two measurements.…”
Section: Discussionmentioning
confidence: 89%
“…Parameters obtained by pressure wave analysis were central pressures (systolic, diastolic, and mean), augmentation index corrected for a heart rate of 75 beats per minute (AIx@HR75), and SEVR. The built-in algorithms (validated in multiple studies as summarized by Weber et al 37 were used to derive these parameters.…”
Section: Non-invasive Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The method was entitled “N-point moving average” (NPMA) ( 47 ). Because of its filtering characteristics, the NPMA method provides aoSBP levels and enables one to obtain aoPP, but in contrast to other methods, no information about aoBP waveforms is given ( 48 ). NPMA was initially proposed as a simple method to estimate aoSBP from RA-derived BP ( 47 ).…”
Section: Methodsmentioning
confidence: 99%