2009 IEEE Biomedical Circuits and Systems Conference 2009
DOI: 10.1109/biocas.2009.5372067
|View full text |Cite
|
Sign up to set email alerts
|

Motion artefact correction for capacitive ECG measurement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
11
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(11 citation statements)
references
References 5 publications
0
11
0
Order By: Relevance
“…Therefore, capacitive electrodes have eliminated the compatibility issues caused by wet and dry electrodes. However, sophistication in capacitive sensor system requires high capacitive coupling to the skin, which may require the use of foreign materials that may suffer from compatibility issues and be susceptible to electrode displacement [5]. Therefore, in this research, the degree to which the conductivity of the electrode, electrode area, insulator thickness, and the dielectric constant of the insulator affect capacitive electrodes fidelity would be examined into details.…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, capacitive electrodes have eliminated the compatibility issues caused by wet and dry electrodes. However, sophistication in capacitive sensor system requires high capacitive coupling to the skin, which may require the use of foreign materials that may suffer from compatibility issues and be susceptible to electrode displacement [5]. Therefore, in this research, the degree to which the conductivity of the electrode, electrode area, insulator thickness, and the dielectric constant of the insulator affect capacitive electrodes fidelity would be examined into details.…”
Section: Introductionmentioning
confidence: 99%
“…The combination of our parameter estimation scheme with the inverse system equations of Heuer et al [13] could be used not only to remove the additive artifact but also to correct for signal distortions, leading to a high-fidelity ECG reconstruction.…”
Section: Discussionmentioning
confidence: 99%
“…To undo the artifacts, they solved the inverse system equation. Their method showed promising results in simulation [12] and controlled bench experiments [13]. However, exact knowledge of all the model parameters (system components and dc voltage across the coupling capacitor) is required.…”
Section: Prior Workmentioning
confidence: 99%
See 1 more Smart Citation
“…accelerators [5], or an injection signal [6]. K Other methods include those based on the wavelet [7] or a reconstruction equation [8].…”
Section: Introductionmentioning
confidence: 99%