Isiame 2012 2012
DOI: 10.1007/978-94-007-6491-0_15
|View full text |Cite
|
Sign up to set email alerts
|

MossWinn—methodological advances in the field of Mössbauer data analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
27
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(27 citation statements)
references
References 4 publications
0
27
0
Order By: Relevance
“…Then, three rounds of measurements, progressively focusing in on temperatures near T c = 6.1 K, were carried out: collecting 24 h with maximum velocity 2 mm/s from 4.3 K to 293.8 K (S1); collecting 48 h with maximum velocity 3 mm/s from 4.4 K to 10 K (S2); collecting 48 h with maximum velocity 3 mm/s from 4.7 K to 6.4 K (S3). All the Mössbauer spectra were fitted by the commercial software package MossWinn [21], in which the standard error of parameters can be estimated either by calculating and inverting the curvature matrix of the χ 2 with respect to the fit parameters, or by the Monte Carlo method. The standard error of IS, quadroupole splitting (QS) and line width (Γ) in this work were obtained from the curvature matrix, while the error the area under the spectra here were obtained by Monte Carlo method by iterating 100 times.…”
Section: Methodsmentioning
confidence: 99%
“…Then, three rounds of measurements, progressively focusing in on temperatures near T c = 6.1 K, were carried out: collecting 24 h with maximum velocity 2 mm/s from 4.3 K to 293.8 K (S1); collecting 48 h with maximum velocity 3 mm/s from 4.4 K to 10 K (S2); collecting 48 h with maximum velocity 3 mm/s from 4.7 K to 6.4 K (S3). All the Mössbauer spectra were fitted by the commercial software package MossWinn [21], in which the standard error of parameters can be estimated either by calculating and inverting the curvature matrix of the χ 2 with respect to the fit parameters, or by the Monte Carlo method. The standard error of IS, quadroupole splitting (QS) and line width (Γ) in this work were obtained from the curvature matrix, while the error the area under the spectra here were obtained by Monte Carlo method by iterating 100 times.…”
Section: Methodsmentioning
confidence: 99%
“…In conclusion, we confidently identified a hedgehog spin-vortex crystal in Co-and Ni-doped After one to two hours at this final temperature the growth assembly was removed from the furnace, inverted into a centrifuge, and spun to decant the remaining liquid off the crystals 35 . The The Mössbauer spectra were fitted using the commercial software package MossWinn 4.0Pre 36 .…”
mentioning
confidence: 99%
“…97 such as humic and fulvic acids, exagluconate (GA), amino acids and citrate are ecophysiological studies (Baker, 2008). In the present paper, the instrument developed 300 the applied fit model we assumed a quadrupole splitting distribution having Gaussian 22 23 24 301 shape and applied the VBF method (Rancourt & Ping, 1991) as implemented in the 25 26 302 MOSSWIN software (Klencsár, 2015). The isomer shift (~0.5 mms -1 ) and quadruploe In order to monitor the chlorosis symptoms in the leaves after the treatment 339 variability of the fluorescence data (error bars in figure 4B) was higher than the SPAD 3 4 340 data (error bars in fig 4C).…”
mentioning
confidence: 99%