1995
DOI: 10.1161/01.cir.91.11.2725
|View full text |Cite
|
Sign up to set email alerts
|

More Rapid, Complete, and Stable Coronary Thrombolysis With Bolus Administration of Reteplase Compared With Alteplase Infusion in Acute Myocardial Infarction

Abstract: r-PA given as a double bolus of 10 + 10 MU achieves more rapid, complete, and sustained thrombolysis of the infarct-related artery than standard-dose TPA, without an apparent increased risk of complications. This was associated with improved global and regional left ventricular function at hospital discharge.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
94
1
3

Year Published

1998
1998
2017
2017

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 256 publications
(98 citation statements)
references
References 27 publications
0
94
1
3
Order By: Relevance
“…30,31 The Recombinant Plasminogen Activator Angiographic Phase II International Dos Finding Study (RAPID) I trial showed that r-PA, when given as a double bolus of 10ϩ10ϫ10 6 U 30 minutes apart, achieves more rapid, complete, and sustained thrombolysis than standard-dose alteplase (100 mg over 3 hours). 32 In the RAPID II trial, the same r-PA dose regimen yielded 90-minute reperfusion rates that were higher than those of front-loaded rt-PA (59.9% versus 45.2%, Pϭ0.01). 33 These promising angiographic findings notwithstanding, r-PA did not achieve superior mortality or clinical outcomes compared with SK (1.5ϫ10 6 U over 60 minutes) in the International Joint Efficacy Comparison of Thrombolytics (INJECT) study.…”
Section: Mutants and Variants Of Rt-pamentioning
confidence: 99%
“…30,31 The Recombinant Plasminogen Activator Angiographic Phase II International Dos Finding Study (RAPID) I trial showed that r-PA, when given as a double bolus of 10ϩ10ϫ10 6 U 30 minutes apart, achieves more rapid, complete, and sustained thrombolysis than standard-dose alteplase (100 mg over 3 hours). 32 In the RAPID II trial, the same r-PA dose regimen yielded 90-minute reperfusion rates that were higher than those of front-loaded rt-PA (59.9% versus 45.2%, Pϭ0.01). 33 These promising angiographic findings notwithstanding, r-PA did not achieve superior mortality or clinical outcomes compared with SK (1.5ϫ10 6 U over 60 minutes) in the International Joint Efficacy Comparison of Thrombolytics (INJECT) study.…”
Section: Mutants and Variants Of Rt-pamentioning
confidence: 99%
“…4,5 Early treatment and complete TIMI grade 3 flow have been facilitated by faster delivery regimens for accelerated alteplase 3 and double-bolus reteplase. [6][7][8] Simpler effective regimens, such as a single-bolus injection, may offer additional benefits through earlier achievement of reperfusion and by reduction in the risk of dosing errors. Efforts to improve thrombolytic efficacy are tempered by the risk of serious bleeding, particularly hemorrhagic stroke.…”
mentioning
confidence: 99%
“…A double bolus regimen (10 C 10 mega units after 30 min) of r-PA administered to patients with AMI helped in complete, speedy, and sustained thrombolysis in comparison with the standard dose of t-PA (front-loaded accelerated infusion or standard infusion). 85,86 This strategy helped to overcome the necessity of a continuous intravenous infusion. The double bolus regimen of r-PA was found to be as effective as the standard dosage of streptokinase (1.5 million units given intravenously over 60 min) for the treatment of AMI (The INJECT Trial, 1995).…”
Section: Third Generation Plasminogen Activatorsmentioning