2004
DOI: 10.1002/9783527612307
|View full text |Cite
|
Sign up to set email alerts
|

More Practical Problem Solving in HPLC

Abstract: This book was carefully produced. Nevertheless, authors and publisher do not warrant the information contained therein to be free of errors. Readers are advised to keep in mind that statements, data, illustrations, procedural details or other items may inadvertently be inaccurate. Library of Congress Card No.: applied forA catalogue record for this book is available from the British Library.Bibliographic information published by Die Deutsche Bibliothek Die Deutsche Bibliothek lists this publication in the Deut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
22
0
4

Year Published

2006
2006
2017
2017

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 18 publications
(27 citation statements)
references
References 0 publications
1
22
0
4
Order By: Relevance
“…Amorphous silica has a weak Bronsted acidity due to the silanol groups. At higher temperatures under laboratory conditions, silica can develop Lewis acidity and basicity due to the activation of siloxane groups during the course of dehydration (Grun et al 1996, Kromidas 2005.…”
Section: Resultsmentioning
confidence: 99%
“…Amorphous silica has a weak Bronsted acidity due to the silanol groups. At higher temperatures under laboratory conditions, silica can develop Lewis acidity and basicity due to the activation of siloxane groups during the course of dehydration (Grun et al 1996, Kromidas 2005.…”
Section: Resultsmentioning
confidence: 99%
“…The selected reference (or pharmacopoeia) method can in principle be used to test for bias in another method under validation. If the proposed electroanalytical method and the reference method agree, this is good evidence they both work for the studied compound and application media such dosage forms, biological material etc [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][17][18][19][20][59][60][61][62]. For obtaining the accuracy from these results, student-t and F tests are generally used for statistical comparison methods [1][2][3][4][5][6][7][8][9][10][11][12][13][14][15][16][59][60][61][62].…”
Section: -Comparison With Results Using Another Reference Methodmentioning
confidence: 99%
“…Then, when the correlation coefficient values reach at least 0.999 the linearity can be assumed in the concentration range for which standard solutions had been prepared during the calibration procedure. However, this parameter is mostly used, but correlation coefficient (r) is neither a proof of linearity nor suitable for quantitative measurement [19,25,[48][49][50][51][52]. Correlation coefficient (r) just indicates the extent of the relationship between the dependent and independent variables such as the electroanalytical response and the electroactive compound concentration.…”
Section: Linearitymentioning
confidence: 99%
See 1 more Smart Citation
“…It is expected that those peaks come from compound components which did not retain in the column. According to literature, the peaks with a retention time of 2 min or less is expected to come from unretained compounds [16]. Thus, the resolution was not affected by the percentage of the organic modifier.…”
Section: Optimization Of Hplc Fingerprint Of Antidiabetic Jamu Extractsmentioning
confidence: 96%