2018
DOI: 10.1016/j.apradiso.2018.01.013
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo dose distribution calculation at nuclear level for Auger-emitting radionuclide energies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 10 publications
(9 citation statements)
references
References 20 publications
0
9
0
Order By: Relevance
“…Figure 5 shows representative models of reference man (A), the kidney (B), or cells (C) used in Monte Carlo Simulation of S-values (Stabin and Siegel 2018; Bouchet et al 2003; Cai et al 2017). Monte Carlo code used to calculate S-values includes MCNP6 (Di Maria et al 2018), PENELOPE (Falzone et al 2017; López-Coello et al 2019), Geant4 (López-Coello et al 2019) and GATE (López-Coello et al 2019). They all allow event-by-event simulation of electron and photon transport.…”
Section: Dosimetric Propertiesmentioning
confidence: 99%
“…Figure 5 shows representative models of reference man (A), the kidney (B), or cells (C) used in Monte Carlo Simulation of S-values (Stabin and Siegel 2018; Bouchet et al 2003; Cai et al 2017). Monte Carlo code used to calculate S-values includes MCNP6 (Di Maria et al 2018), PENELOPE (Falzone et al 2017; López-Coello et al 2019), Geant4 (López-Coello et al 2019) and GATE (López-Coello et al 2019). They all allow event-by-event simulation of electron and photon transport.…”
Section: Dosimetric Propertiesmentioning
confidence: 99%
“…The MIRD committee of the American Nuclear Society of Nuclear Medicine is often used in order to perform dosimetry calculations at subcellular level, by using semi-analytical methods (based on the continuous slowing-down approximation) to calculate the fraction of energy released from the source that is absorbed in the target zone (S-value) [ 25 ]. The radii of cell nucleus and cytoplasm considered in this study are respectively of 2 μm and 4 μm, corresponding to the average values obtained from fluorescence microscopy images of PC3 cells, as we have described previously [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
“…Further discussions about models used to obtain ENDF/B-VI-8 data library can be found in reference [ 31 ]. Single-event mode is a relatively new feature of MCNP6 that was tested and validated in several works present in literature [ 28 , 32 , 33 ]. A validation of the MC model was made through MC S-values calculations (for several radionuclide spectra emission), and results showed agreement with MIRD values within 3% error [ 28 ].…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Multicellular dosimetry is also important for organs and tissue with microstructure (Sgouros et al, 2011). Several studies were performed for calculating the cellular S-coefficients based on analytical and Monte Carlo methods (Bousis et al, 2010;Chegeni et al, 2021;Di Maria et al, 2018;Fourie et al, 2015;Goddu et al, 1994a;Falzone et al, 2017;Ftáčniková and Böhm, 2000;Kouhkan et al, 2020;Lee et al, 2018;Moradi and Bidabadi, 2018;Salim and Taherparvar, 2020;Šefl et al, 2015;Siragusa et al, 2017;Tajik-Mansoury et al, 2017;Tang et al, 2021;Tung et al, 2004;Wu et al, 2012). For example, Goddu et al (1994a) evaluated the cellular S-coefficients for various α, β, and Auger electron emitters for the target←source combinations of cell←cell, cell←cell surface, nucleus←nucleus, nucleus←cytoplasm, and nucleus←cell surface.…”
Section: Radiopharmaceutical Therapymentioning
confidence: 99%