Monte Carlo dose calculation in presence of low-density media: Application to lung SBRT treated during DIBH

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 15 publications
(8 citation statements)
references
References 38 publications
0
7
0
1
Order By: Relevance
“…For these field sizes and a 6-MV photon beam, differences in lateral electron scattering between AAA and AXB is a minor effect that might only affect the periphery of the PTV. 6 , 10 , 14 , 18 , 38 Concerning the depth dose curves, AAA underestimates the dose in the lung surrounding the GTV, but overestimates secondary build-up in the lung-GTV interface, leading to a higher dose in the GTV region. 6 , 10 , 13 , 18 , 38 As our PTVs contained 66.7% lung tissue on average, the first phenomenon outweighed the second, and the AXB-calculated D mean and D 50 were higher than the AAA values.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…For these field sizes and a 6-MV photon beam, differences in lateral electron scattering between AAA and AXB is a minor effect that might only affect the periphery of the PTV. 6 , 10 , 14 , 18 , 38 Concerning the depth dose curves, AAA underestimates the dose in the lung surrounding the GTV, but overestimates secondary build-up in the lung-GTV interface, leading to a higher dose in the GTV region. 6 , 10 , 13 , 18 , 38 As our PTVs contained 66.7% lung tissue on average, the first phenomenon outweighed the second, and the AXB-calculated D mean and D 50 were higher than the AAA values.…”
Section: Discussionmentioning
confidence: 99%
“… 6 , 10 , 14 , 18 , 38 Concerning the depth dose curves, AAA underestimates the dose in the lung surrounding the GTV, but overestimates secondary build-up in the lung-GTV interface, leading to a higher dose in the GTV region. 6 , 10 , 13 , 18 , 38 As our PTVs contained 66.7% lung tissue on average, the first phenomenon outweighed the second, and the AXB-calculated D mean and D 50 were higher than the AAA values. Of the other studies using AXB v11 or later, some reported findings similar to ours with regard to these parameters, 18 , 19 , 20 others found no differences, 22 , 24 and 1 found an underestimation of AXB-predicted D mean of approximately 1%.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Beilla S. et al [13] propose the use of a MC model to assess the quality of dose computation in the context of Stereotactic Body Radiation Therapy (SBRT) during Deep Inspiration Breath Hold (DIBH). A model of the head of a specific LINAC was implemented.…”
Section: Radiotherapymentioning