Monte Carlo calculated TG‐60 dosimetry parameters for the emitter brachytherapy source

Abstract: The results show the advantage of the 153Sm source in comparison with the other sources because of the rapid dose fall-off of beta ray and high dose rate at the short distances of the seed. The results would be helpful in the development of the radioactive implants using 153Sm seeds for the brachytherapy treatment.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
3
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 19 publications
(16 reference statements)
1
3
0
Order By: Relevance
“…7, the radial dose function of the 90Y glass seed is compared to those of the several beta‐emitter seeds. ( 7 , 22 , 23 , 28 , 29 ) As observed in figure, the radial dose function of this seed is approximately similar to those of the 90Srfalse/90normalY, and 142Pr seeds. Also, the decrease in radial dose function for that is slower than to those of the 153Sm,32P, and 114In sources.…”
Section: Resultssupporting
confidence: 68%
See 1 more Smart Citation
“…7, the radial dose function of the 90Y glass seed is compared to those of the several beta‐emitter seeds. ( 7 , 22 , 23 , 28 , 29 ) As observed in figure, the radial dose function of this seed is approximately similar to those of the 90Srfalse/90normalY, and 142Pr seeds. Also, the decrease in radial dose function for that is slower than to those of the 153Sm,32P, and 114In sources.…”
Section: Resultssupporting
confidence: 68%
“…Figure 1 illustrates the sample of desired glass seed. Because of high density of YAS glass, a radio‐opaque marker is not necessary; however, the 103 keV gamma ray emitted by 153Sm can be detected by a gamma camera (23) . Also, cladding or encapsulation is not required because the seed is nonreactive in water or tissue.…”
Section: Methodsmentioning
confidence: 99%
“…Besides, cladding or encapsulation is not required because the seed is unreactive in water or tissue [15]. Furthermore, in one of our previous papers [41], we evaluated dose distribution of the 153 Sm and 142 Pr source for brachytherapy. The MCNP5 Monte Carlo code was used to calculate the quantitative dosimetric parameters suggested in the AAPM TG-60 reports in ranges of millimeters [42].…”
Section: Radiobiological Characteristicsmentioning
confidence: 99%
“… 6 , 27 29 These bioglasses interact with the surrounding tissue in situ and can be absorbed by body after about 7 months. 19 , 21 , 30 …”
Section: Introductionmentioning