2019
DOI: 10.1007/s00411-019-00786-1
|View full text |Cite
|
Sign up to set email alerts
|

Monte Carlo-based determination of radiation leakage dose around a dedicated IOERT accelerator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
3
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 18 publications
0
3
0
1
Order By: Relevance
“…MCNPX (version 2.6) was used in the current study for simulating the intraoperative electron irradiations and relevant photon contamination beneath the studied shielding disks 25,26 . In this regard, A Validated Monte Carlo‐simulated Model of Liac12 head at different intraoperative electron energies was employed 27 . The simulated modules respectively included a Titanium (Ti) exit window, Al scattering foil, air‐filled monitor ion chambers, a Mylar‐made protective layer, sidelong PEEK and PMMA polymer support, and a cylindrical PMMA‐based applicator.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…MCNPX (version 2.6) was used in the current study for simulating the intraoperative electron irradiations and relevant photon contamination beneath the studied shielding disks 25,26 . In this regard, A Validated Monte Carlo‐simulated Model of Liac12 head at different intraoperative electron energies was employed 27 . The simulated modules respectively included a Titanium (Ti) exit window, Al scattering foil, air‐filled monitor ion chambers, a Mylar‐made protective layer, sidelong PEEK and PMMA polymer support, and a cylindrical PMMA‐based applicator.…”
Section: Methodsmentioning
confidence: 99%
“…25,26 In this regard, A Validated Monte Carlo-simulated Model of Liac12 head at different intraoperative electron energies was employed. 27 The simulated modules respectively included a Titanium (Ti) exit window, Al scattering foil, air-filled monitor ion chambers, a Mylar-made protective layer, sidelong PEEK and PMMA polymer support, and a cylindrical PMMA-based applicator. The initial electron energy spectra and their spatial distribution upon the exit window were provided by the manufacturer (Sordina, SpA, Italy).…”
Section: Dedicated Ioert Acceleratormentioning
confidence: 99%
See 1 more Smart Citation
“…La interacción de los electrones con los diversos componentes del LINAC conduce a la dispersión de los mismos así como a la producción de fotones secundarios. El impacto de tales partículas en el cuerpo mismo del paciente puede elevar las probabilidades de padecer cáncer, por estas razones conviene conocer y cuantificar este tipo de radiación secundaria [2]. El estudio de la generación de radiación secundaria incluye también la producción de neutrones debida a la aceleración de electrones en LINAC's empleados en radioterapia intraoperatoria (IORT).…”
Section: Introductionunclassified