2015
DOI: 10.3855/jidc.6959
|View full text |Cite
|
Sign up to set email alerts
|

Monoclonal antibodies for characterization of rabies virus isolated from non-hematophagous bats in Brazil

Abstract: Introduction: In Brazil, various isolates of rabies virus (RABV) show antigenic profiles distinct from those established by the reduced panel of eight monoclonal antibodies (MAbs) determined by the Centers for Disease Control and Prevention (CDC), utilized for the antigenic characterization of RABV in the Americas. The objective of this study was to produce MAbs from RABV isolates from insectivorous bats with an antigenic profile incompatible with the pre-established one. Methodology: An isolate of RABV from t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(4 citation statements)
references
References 33 publications
(40 reference statements)
0
3
0
1
Order By: Relevance
“…Sensitive, specific, economical, and timely diagnostic tests have been available for more than 50 years, and there has been increasing augmentation by molecular methods for routine rabies diagnosis 10 , 36 , 37 . Yet despite the innumerable rabies cases that occur in wildlife, domestic animals, and humans on a daily basis, only a very small fraction are diagnosed.…”
Section: Neglect Of Laboratory-based Surveillance Systemsmentioning
confidence: 99%
“…Sensitive, specific, economical, and timely diagnostic tests have been available for more than 50 years, and there has been increasing augmentation by molecular methods for routine rabies diagnosis 10 , 36 , 37 . Yet despite the innumerable rabies cases that occur in wildlife, domestic animals, and humans on a daily basis, only a very small fraction are diagnosed.…”
Section: Neglect Of Laboratory-based Surveillance Systemsmentioning
confidence: 99%
“…The RFFIT was conducted in duplicate on 72 serum samples, following the method described by Smith et al [20], with some modifications [21]. A human international standard rabies immune globulin (SRIG) reference serum of 30 IU/mL (National Institute for Biological Standards and Control, Herts, UK) recognized by the World Health Organization (WHO) was diluted to 0.5 IU/mL.…”
Section: Detection Of Rabv Virus-neutralizing Antibodiesmentioning
confidence: 99%
“…Early laboratory diagnosis of rabies is crucial to confirm the status of a suspect case, in order to justify prophylactic treatment in exposed people or animals. Sensitive, specific, economical and timely diagnostic tests have been available for more than 50 years, with the more recent development of molecular methods for routine rabies diagnosis (21,22,23,24).…”
Section: Laboratory Requirementsmentioning
confidence: 99%