2013
DOI: 10.1007/s00264-013-2210-0
|View full text |Cite
|
Sign up to set email alerts
|

Mono- versus polyaxial locking plates in distal femur fractures: a prospective randomized multicentre clinical trial

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
18
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 42 publications
(21 citation statements)
references
References 21 publications
(20 reference statements)
0
18
0
Order By: Relevance
“…The aspect of plating can also be extended to the question of single vs double plating respectively mono vs polyaxial locking plates in periprosthetic fractures as mono axial plates often used in combination with double plating was preferred in some cases so far. Hanschen et al could demonstrate that single plating with polyaxial locking plates in complex distal femur fractures leads to good functional and clinical results [ 21 ]. Regarding the soft tissue management as well as the outcome in the treatment of Felix fractures so far, the transfer of this aspect to the tibial side should be well considered.…”
Section: Discussionmentioning
confidence: 99%
“…The aspect of plating can also be extended to the question of single vs double plating respectively mono vs polyaxial locking plates in periprosthetic fractures as mono axial plates often used in combination with double plating was preferred in some cases so far. Hanschen et al could demonstrate that single plating with polyaxial locking plates in complex distal femur fractures leads to good functional and clinical results [ 21 ]. Regarding the soft tissue management as well as the outcome in the treatment of Felix fractures so far, the transfer of this aspect to the tibial side should be well considered.…”
Section: Discussionmentioning
confidence: 99%
“…That can often leads to positioning of screws in bone areas which intraoperatively have to be considered of minor quality. This may be associated with secondary loss of realignment and loosening of screws[ 15 ]. Ideas to avoid this and giving the surgeon more freedom in directing the screws through the bone lead to the introduction of polyaxial locking plates[ 16 ].…”
Section: Introductionmentioning
confidence: 99%
“…To the editor, Hanschen et al [1] have done an excellent study on monoversus polyaxial locking plates in distal femur fractures, which found the polyaxial treatment tended to result in better functional and radiological outcome. However, we have some concerns regarding the paper and wish to share them.…”
mentioning