2021
DOI: 10.1186/s12967-021-03060-5
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring the tissue perfusion during hemorrhagic shock and resuscitation: tissue-to-arterial carbon dioxide partial pressure gradient in a pig model

Abstract: Background Despite much evidence supporting the monitoring of the divergence of transcutaneous partial pressure of carbon dioxide (tcPCO2) from arterial partial pressure carbon dioxide (artPCO2) as an indicator of the shock status, data are limited on the relationships of the gradient between tcPCO2 and artPCO2 (tc-artPCO2) with the systemic oxygen metabolism and hemodynamic parameters. Our study aimed to test the hypothesis that tc-artPCO2 can detect inadequate tissue perfusion during hemorrha… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 46 publications
(45 reference statements)
0
5
0
Order By: Relevance
“…*The placement of the femoral vein catheter tip was accurately localized at the opening of the right atrium using ultrasound guidance. Consequently, mixed venous oxygen saturation (SvO 2 ) was substituted with central venous oxygen saturation (ScvO 2 ) for this study ( Endo et al, 2021 ).…”
Section: Methodsmentioning
confidence: 99%
“…*The placement of the femoral vein catheter tip was accurately localized at the opening of the right atrium using ultrasound guidance. Consequently, mixed venous oxygen saturation (SvO 2 ) was substituted with central venous oxygen saturation (ScvO 2 ) for this study ( Endo et al, 2021 ).…”
Section: Methodsmentioning
confidence: 99%
“…In all animals, we measured the TPTD parameters using the PiCCO monitoring system [ 22 ]. TPTD was precisely conducted as previously described [ 22 ].…”
Section: Methodsmentioning
confidence: 99%
“…In all animals, we measured the TPTD parameters using the PiCCO monitoring system [ 22 ]. TPTD was precisely conducted as previously described [ 22 ]. Briefly, (1) we used 10 mL of 0 °C physiological saline 0.9% as an indicator, (2) use of average of three times values, (3) the indicator was injected by the same operator (YE) throughout the experiment, (4) the indicator was injected for 2–3 s, (5) ΔT in TPTD (the change in blood temperature after indicator injection) was recorded; optimal = ΔT > 0.3, good = ΔT > 0.2, and bad = ΔT < 0.2, to verify the reliability of the measurement method.…”
Section: Methodsmentioning
confidence: 99%
“…He presented the results of his work using a pig model to validate tissue‐to‐arterial carbon dioxide partial pressure gradient during hemorrhagic shock and resuscitation as a noninvasive measure of hemorrhagic shock. 33 …”
Section: Interventions and Therapies In Resuscitation Sciencementioning
confidence: 99%