Monitoring proton radiation therapy with in-room PET imaging

Abstract: Purpose We used a mobile PET scanner positioned within the proton therapy treatment room to study the feasibility of proton range verification with an in-room, stand-alone PET system, and compared with off-line equivalent studies. Methods and materials Two subjects with adenoid cystic carcinoma were enrolled into a pilot study in which in-room PET scans were acquired in list-mode after a routine fractionated treatment session. The list-mode PET data were reconstructed with different time schemes to generate … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
110
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 103 publications
(110 citation statements)
references
References 18 publications
0
110
0
Order By: Relevance
“…At present, the only clinically implemented approach to monitor the delivery of single treatment fractions shortly after irradiation relies on the detection of irradiation-induced β + -emitters within the patient by means of positron emission tomography (PET) imaging. [5][6][7][8][9] At the Heidelberg Ion-Beam Therapy Center (HIT), 10,11 a commercial full-ring PET/x-ray computed tomography (CT) scanner [Biograph mCT, Siemens Molecular Imaging, Knoxville (Ref. 12)] has been installed next to the treatment rooms (offline) for this purpose.…”
Section: Introductionmentioning
confidence: 99%
“…At present, the only clinically implemented approach to monitor the delivery of single treatment fractions shortly after irradiation relies on the detection of irradiation-induced β + -emitters within the patient by means of positron emission tomography (PET) imaging. [5][6][7][8][9] At the Heidelberg Ion-Beam Therapy Center (HIT), 10,11 a commercial full-ring PET/x-ray computed tomography (CT) scanner [Biograph mCT, Siemens Molecular Imaging, Knoxville (Ref. 12)] has been installed next to the treatment rooms (offline) for this purpose.…”
Section: Introductionmentioning
confidence: 99%
“…Shakirin et al [11] described three different techniques: inbeam PET (PET cameras with limited angle geometry, fully integrated into the treatment site) [12], off-line PET (the usage of a standard PET-CT scanner outside the treatment room) [13] and in-room PET (full ring PET scanner inside the treatment room). In-room PET may also utilize a portable PET scanner [14,15]. Regarding off-line PET the most important limitation is the extensive influence of the patient metabolism [13,16,17].…”
Section: Introductionmentioning
confidence: 99%
“…The in-room PET method is based on the measurement immediately after irradiation by a standalone PET or PET/ CT scanner that is installed inside the treatment room. In this method, the patient does not have to be repositioned in the bed, which is moved from the treatment position to inside the PET scanner in 1-3 minutes, which is still big compared to the half-life of 150 and washout effects are still present [10], [11]. The in-beam PET concept relies on the PET measurement performed during and right after the irradiation by means of a PET scanner, which is integrated in the beam line [12].…”
Section: Iintroductionmentioning