2014
DOI: 10.1016/j.geothermics.2013.10.013
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring of induced seismicity during the first geothermal reservoir stimulation at Paralana, Australia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
54
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 61 publications
(56 citation statements)
references
References 36 publications
2
54
0
Order By: Relevance
“…As shown by Albaric et al (2014), the hypocentres of the first three of these events were located at the periphery of the extent of the seismic cloud at that time, whereas the fourth occurred closer to the well, in a zone which had experienced activity earlier during the stimulation process (Fig. 5).…”
Section: Paralana Australiamentioning
confidence: 87%
See 3 more Smart Citations
“…As shown by Albaric et al (2014), the hypocentres of the first three of these events were located at the periphery of the extent of the seismic cloud at that time, whereas the fourth occurred closer to the well, in a zone which had experienced activity earlier during the stimulation process (Fig. 5).…”
Section: Paralana Australiamentioning
confidence: 87%
“…In Europe, locations include the Lower Rhine Graben site in Soultz-sous-Forêts, France (Evans et al, 2005), the Upper Rhine Graben site in Basel, Switzerland (Häring et al, 2008), Icelandic geothermal test sites , Latera (Italy) and Groß Schönebeck in the North German Basin (Kwiatek et al, 2010). Non-European sites investigated include Berlin, El Salvador (Bommer et al, 2006;Kwiatek et al, 2014), The Geysers in California, USA (Oppenheimer, 1986;Majer et al, 2007), Cooper Basin (Asanuma et al, 2005;Baisch et al, 2006) and Paralana (Hasting et al, 2011;Albaric et al, 2014), both in Australia and Bouillante in Guadeloupe (Sanjuan et al, 2010;Calcagno et al, 2012). Two reference sites were included, where seismicity was induced by other than geothermal causes.…”
Section: Seismic Response To Fluid Injection: Network Design Velocitmentioning
confidence: 99%
See 2 more Smart Citations
“…Furthermore, using residual phase tensor analysis, (Peacock, et al 2013) demonstrated that the injected fluids propagated along pre-existing fault system oriented in a NNE direction. The micro-seismic survey conducted at Paralana EGS showed fractures opened in a NNE, NE, and ENE direction along pre-existing fault systems (Albaric, et al 2014, Hasting, et al 2011. These studies showed the complementarity of MT and micro-seismics in characterizing fluid injection into EGS reservoirs.…”
Section: Introductionmentioning
confidence: 99%