2020
DOI: 10.4136/ambi-agua.2603
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring of fluoride in the public water supply using electrometric or colorimetric analyses

Abstract: The surveillance of the concentration of fluoride in the public water supply aims to ensure the balance between the benefits (carie prevention) and risk (dental fluorosis) of water fluoridation programs. The aim of this study was to check the accuracy of two analytical methods for monitoring the concentration of fluoride in the public water supply of a Brazilian city. The STROBE checklist was used to aid the conduction of this study and report the results. It was an analytical, observational, and prospective s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 25 publications
0
4
0
Order By: Relevance
“…In our study, the two techniques had a strongly positive correlation (r= 0.91), which may demonstrate the potential for using the colorimetric technique, when calibration is carried out with the electrometric technique. Importantly, in our study, the analyses were carried out by different institutions in a blind manner, in contrast to other studies conducted in the same laboratory [15][16][17] . In addition, one of these studies used a SPADNS kit of analysis, which can present limited results, compared to a standardized methodology of analysis.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…In our study, the two techniques had a strongly positive correlation (r= 0.91), which may demonstrate the potential for using the colorimetric technique, when calibration is carried out with the electrometric technique. Importantly, in our study, the analyses were carried out by different institutions in a blind manner, in contrast to other studies conducted in the same laboratory [15][16][17] . In addition, one of these studies used a SPADNS kit of analysis, which can present limited results, compared to a standardized methodology of analysis.…”
Section: Discussionmentioning
confidence: 99%
“…Nevertheless, according to Brossok et al 16 (1987), Weinberger et al 17 (1989), Edelstein et al 18 (1992), and Lins-Candeiro et al 15 (2020), the colorimetric technique tends to give a higher value than the electrometric one, overestimating F concentration compared to the ISE technique. On the other hand, in Motter's study 14 , the colorimetric method resulted in a lower value than the electrometric technique.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations