2010
DOI: 10.1002/rcm.4570
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring chloramines and bromamines in a humid environment using selected ion flow tube mass spectrometry

Abstract: The selectivity and sensitivity of selected ion flow tube mass spectrometry (SIFT-MS) for individual breath analysis of haloamines has been improved by heating the flow tube in a commercial instrument to around 106 degrees C. Data is presented showing the marked reduction in the number density of water clusters of product ions of common breath metabolites that are isobaric with the product ions from monochloramine and monobromamine that are used to monitor the haloamine concentrations. These results have direc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
8
0

Year Published

2010
2010
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 16 publications
0
8
0
Order By: Relevance
“…From the reconstructed signal, as we use chemical ionization, it is possible to evaluate the concentration of the permeate gas knowing the capture rate constant k C [18]. We used the value calculated by Senthiloman et al [17]: k = 3.0 × 10 −9 cm 3 ·s −1 .…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…From the reconstructed signal, as we use chemical ionization, it is possible to evaluate the concentration of the permeate gas knowing the capture rate constant k C [18]. We used the value calculated by Senthiloman et al [17]: k = 3.0 × 10 −9 cm 3 ·s −1 .…”
Section: Resultsmentioning
confidence: 99%
“…Two compact FTICR mass spectrometers have been used: Btrap2, for the study on different precursors, and MICRA (mobile ICR analyzer) [18] for the other experiments. Btrap2 is an instrument developed by AlyXan (Juvisy-sur-Orge, France): it is fully automated and uses a 1 T permanent magnet.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…21,80,187 A chart of some successful areas of application that have been piloted is given in Table 3. Extension of SIFT-MS to other areas of ambient analysis is an on-going procedure as we, and others (notably Ross and co-workers, 60,69,[188][189][190] Turner and coworkers, 186,191 food scientists at Ohio State University 192 and McEwan and co-workers [61][62][63][193][194][195][196] ) continuously recognize the value of real time SIFT-MS analyses.…”
Section: Some Other Applicationsmentioning
confidence: 99%
“…Recently we reported an improved SIFT-MS method for the measurement of mono-and di-chloramine and monobromamine in humid samples such as breath [8]. Earlier SIFT-MS analysis [2] had not taken into account the water cluster product ions of some common breath volatiles (NH 3 , CH 3 OH, CH 3 COCH 3 and CH 3 CO 2 H) that are isobaric with the product ions of the haloamines.…”
Section: Introductionmentioning
confidence: 99%