2021
DOI: 10.3389/fonc.2021.601784
|View full text |Cite
|
Sign up to set email alerts
|

Monitoring Carbon Ion Beams Transverse Position Detecting Charged Secondary Fragments: Results From Patient Treatment Performed at CNAO

Abstract: Particle therapy in which deep seated tumours are treated using 12C ions (Carbon Ions RadioTherapy or CIRT) exploits the high conformity in the dose release, the high relative biological effectiveness and low oxygen enhancement ratio of such projectiles. The advantages of CIRT are driving a rapid increase in the number of centres that are trying to implement such technique. To fully profit from the ballistic precision achievable in delivering the dose to the target volume an online range verification system wo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 13 publications
(12 citation statements)
references
References 25 publications
0
12
0
Order By: Relevance
“…Finally, although the focus of this manuscript has been on proton therapy scenarios, it is a physics fact that FNs and PGs are also produced abundantly in other PT modalities such as He- and C-ion therapy 22 , 27 , 28 where the same clinical challenges related to range uncertainties are also present. Therefore, it is expected that the use cases of the NOVCoDA can also be extended to range-monitoring applications within these therapy modalities to further reduce treatment toxicities.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Finally, although the focus of this manuscript has been on proton therapy scenarios, it is a physics fact that FNs and PGs are also produced abundantly in other PT modalities such as He- and C-ion therapy 22 , 27 , 28 where the same clinical challenges related to range uncertainties are also present. Therefore, it is expected that the use cases of the NOVCoDA can also be extended to range-monitoring applications within these therapy modalities to further reduce treatment toxicities.…”
Section: Discussionmentioning
confidence: 99%
“…Also, in light of previous results reported in other simulation studies, such as the one by Smeets et al 8 , where range shift detection sensitivities of 1 mm have been achieved down to intensities of 5 × 10 8 protons/spot, it can be stated that the results of this work show that the NOVCoDA could be a feasible approach to range monitoring in PT. Finally, although the focus of this manuscript has been on proton therapy scenarios, it is a physics fact that FNs and PGs are also produced abundantly in other PT modalities such as He-and C-ion therapy 22,27,28 where the same clinical challenges related to range uncertainties are also present. Therefore, it is expected that the use cases of the NOVCoDA can also be extended to range-monitoring applications within these therapy modalities to further reduce treatment toxicities.…”
Section: Discussionmentioning
confidence: 99%
“…In the case of patients in which morphological changes occurred, the Dose Profiler was able to detect the discrepancy using the χ 2 test. Moreover, the clinical data acquired allowed to study the capability of the Dose Profiler to monitor in vivo the actual transverse position of the beam [50].…”
Section: In Vivo Range Verificationmentioning
confidence: 99%
“…Finally, although the focus of this manuscript has been on proton therapy scenarios, it is a physics fact that FNs and PGs are also produced abundantly in other PT modalities such as He-and C-ion therapy [22,27,28] where the same clinical challenges related to range uncertainties are also present. Therefore, it is expected that the use cases of the QuDA can also be extended to range-monitoring applications within these therapy modalities to further reduce treatment toxicities.…”
Section: Pt Holds Great Potential To Reduce Integral Dose To Healthy ...mentioning
confidence: 99%