The 17th Asia Pacific Conference on Communications 2011
DOI: 10.1109/apcc.2011.6152769
|View full text |Cite
|
Sign up to set email alerts
|

Monitored power pre-checking scheme for optical amplification management in lightpath reconfigurable IP-over-CWDM networks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2011
2011
2014
2014

Publication Types

Select...
2
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 6 publications
0
4
0
Order By: Relevance
“…The monitored power P 3 is used for the P 2 estimation to judge in the CMS whether P 2 is smaller than the minimum detectable power P min of the OTR, i.e. the lightpath should be amplified or not [7]. For the estimation, the measured difference P 2 -P 3 is used as a correction coefficient for better estimation.…”
Section: Basic Design Of Stackable Module With Anmentioning
confidence: 99%
See 1 more Smart Citation
“…The monitored power P 3 is used for the P 2 estimation to judge in the CMS whether P 2 is smaller than the minimum detectable power P min of the OTR, i.e. the lightpath should be amplified or not [7]. For the estimation, the measured difference P 2 -P 3 is used as a correction coefficient for better estimation.…”
Section: Basic Design Of Stackable Module With Anmentioning
confidence: 99%
“…Based on the proposed amplifier modules, the amplification management scheme was investigated and evaluated together with the amplifier module, clarifying how it is decided which lightpaths are to be amplified before the lightpath reconfiguration. The amplification management function is described in detail in other paper [7], and the structure of the proposed module with an amplifier is presented and the fundamental characteristics are described in this paper.…”
Section: Introductionmentioning
confidence: 99%
“…The P r value can be calculated by (1), but the values used in (1) are different from the actual values due to measurement errors and the degradation by aging. Therefore, an amplification management scheme was designed [7] such that the P r value is obtained by a power monitor (PM) in the network as described below.…”
Section: Basic Design Of Stackable Module With An Optical Amplifiermentioning
confidence: 99%
“…We propose a stackable module with a bidirectional CWDM amplifier, enabling us to introduce the optical amplifier in a fully compatible way to the existing S‐ROADMs. Based on the proposed amplifier modules, the amplifier control function was investigated and implemented [7] by adding the function to the existing system for lightpath reconfiguration by the S‐ROADMs. This amplifier control function includes how it is decided which lightpaths are to be amplified before the lightpath reconfiguration.…”
Section: Introductionmentioning
confidence: 99%