2022
DOI: 10.1016/j.bios.2022.114073
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymer-based electrochemical impedimetric sensors on screen-printed carbon electrodes for the detection of trace cytokine IL-1β

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
19
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 31 publications
0
19
0
Order By: Relevance
“…Using biomimetic elements, such as MIPs, brings important benefits in increasing the selectivity of sensors. Numerous MIPs have been developed for biomedical applications 150–154 . Thus, a highly sensitive, accurate, and fast biomimetic detection device was fabricated for IL‐6 detection in human serum, the MIP film being prepared on a SPE of carbon by the co‐electropolymerization of pyrrole and carboxylated pyrrole in the presence of IL‐6 150 …”
Section: Analytical Methods Applied For Cytokines Determination In Bi...mentioning
confidence: 99%
See 3 more Smart Citations
“…Using biomimetic elements, such as MIPs, brings important benefits in increasing the selectivity of sensors. Numerous MIPs have been developed for biomedical applications 150–154 . Thus, a highly sensitive, accurate, and fast biomimetic detection device was fabricated for IL‐6 detection in human serum, the MIP film being prepared on a SPE of carbon by the co‐electropolymerization of pyrrole and carboxylated pyrrole in the presence of IL‐6 150 …”
Section: Analytical Methods Applied For Cytokines Determination In Bi...mentioning
confidence: 99%
“…A double layer comprising poly(o‐phenylenediamine), poly(chromotrope 2R) was formed to generate a MIP film at the carbon‐based SPE for the highly sensitive and selective detection of IL‐1β in complex matrix 151 …”
Section: Analytical Methods Applied For Cytokines Determination In Bi...mentioning
confidence: 99%
See 2 more Smart Citations
“…In addition, MIP materials have demonstrated several important benefits in electrochemical sensors including (i) easy preparation, (ii) low cost, (iii) storage stability, (iv) repeated use without deterioration of performance, and (v) resistance to pressure, heat, and harsh chemical conditions. 3–6 These benefits have enabled MIP based electrochemical sensors to fulfil the needs of the development of standard analytical techniques, which can be used in day-to-day experiments while also achieving good performance for numerous repetitions.…”
Section: Introductionmentioning
confidence: 99%