2009
DOI: 10.1016/j.aca.2009.04.016
|View full text |Cite
|
Sign up to set email alerts
|

Molecularly imprinted polymer as micro-solid phase extraction combined with high performance liquid chromatography to determine phenolic compounds in environmental water samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
40
0
1

Year Published

2012
2012
2018
2018

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 113 publications
(47 citation statements)
references
References 31 publications
2
40
0
1
Order By: Relevance
“…Magnetic MIPs can be easily separated from sample solution using an external magnetic field without additional centrifugation or filtration, which simplifies the extraction procedure [32], but the MEKC analysis needs longer time to separate three chlorophenols than our method. The obtained LODs were lower than that of the HPLC [30,31] or comparable to that of the GC [39] methods, except the method of online LVSS coupled with MEKC [32]. Nevertheless, the benefits of MIPs-DSPE-CE method are still obvious, like high sensitivity and selectivity, simple a) y and x stand for the peak area and the concentration (g/L) of all the analytes, respectively.…”
Section: Methods Performancementioning
confidence: 99%
See 2 more Smart Citations
“…Magnetic MIPs can be easily separated from sample solution using an external magnetic field without additional centrifugation or filtration, which simplifies the extraction procedure [32], but the MEKC analysis needs longer time to separate three chlorophenols than our method. The obtained LODs were lower than that of the HPLC [30,31] or comparable to that of the GC [39] methods, except the method of online LVSS coupled with MEKC [32]. Nevertheless, the benefits of MIPs-DSPE-CE method are still obvious, like high sensitivity and selectivity, simple a) y and x stand for the peak area and the concentration (g/L) of all the analytes, respectively.…”
Section: Methods Performancementioning
confidence: 99%
“…As seen, the CE analysis of seven phenols needs shorter time (ß13 min) than HPLC (16-20 min) [30,31], MEKC (ß 35 min) [32] and GC (ß 20 min) [39]. For DSPE procedure, MIPs polymers are completely dispersed in sample solution, which increases the contact opportunity of target analytes and shortens the extraction time.…”
Section: Methods Performancementioning
confidence: 99%
See 1 more Smart Citation
“…The MIMSPE device consists of the MIPs enclosed within a polypropylene flat-sheet membrane envelope which is shown in Figure 1 and the preparation procedure was the same as reported before [20].…”
Section: Preparation Of the Mimspementioning
confidence: 99%
“…In recent years, MIPs proved to be useful materials in several areas of analytical chemistry [5,[16][17][18][19][20]. MIPs are synthetic materials with artificially-generated recognition sites able to specifically rebind a target molecule in preference to other closely-related compounds.…”
Section: Molecularly-imprinted Polymersmentioning
confidence: 99%