2014
DOI: 10.1117/12.2064808
|View full text |Cite
|
Sign up to set email alerts
|

Molecular imaging in the College of Optical Sciences: an overview of two decades of instrumentation development

Abstract: During the past two decades, researchers at the University of Arizona’s Center for Gamma-Ray Imaging (CGRI) have explored a variety of approaches to gamma-ray detection, including scintillation cameras, solid-state detectors, and hybrids such as the intensified Quantum Imaging Device (iQID) configuration where a scintillator is followed by optical gain and a fast CCD or CMOS camera. We have combined these detectors with a variety of collimation schemes, including single and multiple pinholes, parallel-hole col… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 55 publications
(54 reference statements)
0
2
0
Order By: Relevance
“…An additional group received saline as a vehicle control (n=6). Mice were imaged at 30 min, 120 min and 240 min after radiotracer injection using a Quantum Imaging Detector (iQID) camera (42)(43)(44). This small-animal imaging system provides imaging of photon and particle emissions in small animals and tissues with high spatial resolution.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…An additional group received saline as a vehicle control (n=6). Mice were imaged at 30 min, 120 min and 240 min after radiotracer injection using a Quantum Imaging Detector (iQID) camera (42)(43)(44). This small-animal imaging system provides imaging of photon and particle emissions in small animals and tissues with high spatial resolution.…”
Section: Discussionmentioning
confidence: 99%
“…In separate experiments (n=3 mice), either Cy5.5-ALT-300 or Cy5.5-IgG (15-20 µg) was injected intravenously 3h after the second TPA/PBS application, followed by mouse imaging. To assess the capacity of the 99m Tc-ALT-300 probe to detect in vivo NAMPT tissue expression, 99m Tc-ProNamptor TM (1.0-1.5 mCi, >98% radiochemical purity), [40,41] or IgG control Ab was intravenously injected at 3h post LPS challenge in the -one-hit‖ model and imaged (Quantum Imaging Detector camera) [42][43][44]. Count activity-based measurements of 99m Tc-ProNamptor TM biodistribution and ex vivo autoradiography were performed in harvested lungs (see…”
Section: Mmentioning
confidence: 99%