2021
DOI: 10.1002/aic.17335
|View full text |Cite
|
Sign up to set email alerts
|

Molecular dynamics study on membrane fouling by oppositely charged proteins

Abstract: Membrane fouling continues to hamper the performance of membrane‐filtration processes. A challenge with macromolecular foulants like proteins is that macroscopic characterizations, like net electrical charge, may be poorly correlated with membrane fouling. This necessitates a molecular‐scale analysis of the local interactions. In this study, molecular dynamics simulations have been performed to understand the interactions between two similar‐sized proteins with opposite overall charges (namely, lysozyme and α‐… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(13 citation statements)
references
References 75 publications
0
13
0
Order By: Relevance
“…Simulation models have to be validated against experiments to ensure reliability and accuracy. Composition of feed/membrane [92,93] Conductivity [36,94] Cross-linking degree [95,96] Contact angle [97,98] Density of grafting sites on the membrane surface [26,29] DOTM A [55] Density of membrane [30,40,99,100] Flux decline profile [30,33,37,101] Spectroscopy (e.g., XPS B , FTIR C ) [35,102,103] Isotherm of static adsorption (e.g., by QCM-D D ) [104][105][106] Zeta potential [107] Rejection of foulant [35,102] SEM E…”
Section: Model Validationmentioning
confidence: 99%
See 4 more Smart Citations
“…Simulation models have to be validated against experiments to ensure reliability and accuracy. Composition of feed/membrane [92,93] Conductivity [36,94] Cross-linking degree [95,96] Contact angle [97,98] Density of grafting sites on the membrane surface [26,29] DOTM A [55] Density of membrane [30,40,99,100] Flux decline profile [30,33,37,101] Spectroscopy (e.g., XPS B , FTIR C ) [35,102,103] Isotherm of static adsorption (e.g., by QCM-D D ) [104][105][106] Zeta potential [107] Rejection of foulant [35,102] SEM E…”
Section: Model Validationmentioning
confidence: 99%
“…It should be noted that there is no universal threshold value for separation distance that can be used to distinguish whether a foulant is adsorbed or unabsorbed, so variour studies have sought different means to determine adsorption or lack thereof. We have used the average separation distance (𝑑 ̅ ) and fraction of time whereby the separation distance is less than 4 Å (𝑓 4 ) to classify MD trajectories into categories of stable adsorption, transient adsorption, and no adsorption [33,107]. Another quantity commonly used to compare adsorption is the number of contact atoms that are within a specified distance from the membrane surface.…”
Section: Separation Distancementioning
confidence: 99%