2010
DOI: 10.1021/jp101238k
|View full text |Cite
|
Sign up to set email alerts
|

Molecular Design of Anthracene-Bridged Metal-Free Organic Dyes for Efficient Dye-Sensitized Solar Cells

Abstract: A series of metal-free organic dyes bridged by anthracene-containing π-conjugations were designed and synthesized as new chromophores for the application of dye-sensitized solar cells (DSCs). Detailed investigations on the relationship between the dye structures, photophysical properties, electrochemical properties, and performances of DSCs are described. With the introduction of the anthracene moiety, together with a triple bond for the fine-tuning of molecular planar configurations and to broaden absorption … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
127
0

Year Published

2012
2012
2017
2017

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 219 publications
(130 citation statements)
references
References 56 publications
3
127
0
Order By: Relevance
“…For TPA-AC3, the calculated main emission band locates at 631 nm, which shows good agreement with experimental data, with a mean absolute deviation of 16 nm or 0.05 eV. [25] The calculated fluorescence emission spectra of TPA-AC1 to TPA-AC5 in CH 2 Cl 2 solutions are depicted in Figure 4, where the UV/Vis peak half-width at half height is 0.33 eV and the unit of fluorescence is cm À1 L mol À1 . As expected, the fluorescence maxima are red-shifted from 486 to 1013 nm from TPA-AC1 to TPA-AC5.…”
Section: Uv/visible and Fluorescence Spectrum Propertiessupporting
confidence: 78%
See 4 more Smart Citations
“…For TPA-AC3, the calculated main emission band locates at 631 nm, which shows good agreement with experimental data, with a mean absolute deviation of 16 nm or 0.05 eV. [25] The calculated fluorescence emission spectra of TPA-AC1 to TPA-AC5 in CH 2 Cl 2 solutions are depicted in Figure 4, where the UV/Vis peak half-width at half height is 0.33 eV and the unit of fluorescence is cm À1 L mol À1 . As expected, the fluorescence maxima are red-shifted from 486 to 1013 nm from TPA-AC1 to TPA-AC5.…”
Section: Uv/visible and Fluorescence Spectrum Propertiessupporting
confidence: 78%
“…Especially for BHandH, the discrepancy between calculated and experimental results is within 36 nm or 0.2 eV. The long-range-corrected CAM-B3LYP provides the most stable and reliable results, predicting excitation energies very close to experimental data [25] with an absolute deviation of 27 nm or 0.15 eV, which is smaller than the generally accepted upper limit required for the design of new industrial dyes (0.2 eV). Therefore, on the basis of the agreement with experimental data, CAM-B3LYP is the functional of choice for the UV/Vis spectra calculation.…”
Section: Computational Detailsmentioning
confidence: 70%
See 3 more Smart Citations