Modulation Scheme Analysis for Low-Power Leadless Pacemaker Synchronization Based on Conductive Intracardiac Communication

Abstract: Conductive intracardiac communication (CIC) has been demonstrated as a promising concept for the synchronization of multi-chamber leadless cardiac pacemakers (LLPMs). To meet the 2-5 µW power budget of a LLPM, highly specialized CIC-transceivers, which make optimal use of the cardiac communication channel, need to be developed. However, a detailed investigation of the optimal communication parameters for CIC-based LLPM synchronization is missing so far. This work analyzes the intracardiac communication perform… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
0
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 27 publications
0
0
0
Order By: Relevance
“…Moreover, relying on an external primary device increases the system's complexity and the risk of complications and may also compromise patient comfort. In the second category, RF communication and galvanic-coupled CIC have been extensively studied for direct implant-to-implant synchronization [6], [12], [17]- [23]. However, RF communication has not achieved adequately low power levels [17], [18].…”
Section: A Related Workmentioning
confidence: 99%
See 4 more Smart Citations
“…Moreover, relying on an external primary device increases the system's complexity and the risk of complications and may also compromise patient comfort. In the second category, RF communication and galvanic-coupled CIC have been extensively studied for direct implant-to-implant synchronization [6], [12], [17]- [23]. However, RF communication has not achieved adequately low power levels [17], [18].…”
Section: A Related Workmentioning
confidence: 99%
“…In contrast, CIC has been demonstrated as an energy-efficient communication method for implant synchronization. This is attributed to the moderate attenuation of the intracardiac channel, relatively high electrode impedance (typically in the range of a few hundred ohms), and the utilization of low-frequency signals (ranging from 1 kHz to 20 MHz) [6], [12], [19]- [23].…”
Section: A Related Workmentioning
confidence: 99%
See 3 more Smart Citations