Modularized Control Strategy and Performance Analysis of DFIG System Under Unbalanced and Harmonic Grid Voltage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
40
0
1

Year Published

2017
2017
2024
2024

Publication Types

Select...
5
1
1

Relationship

2
5

Authors

Journals

citations
Cited by 61 publications
(41 citation statements)
references
References 19 publications
0
40
0
1
Order By: Relevance
“…Thus, impedance modeling needs to take the influence of transformer configuration. Equation (9), moreover, (10) can be rewritten as (11) and (12) by supposing the turn ratios of the primary and secondary side are K r = V PCC /V 1 and K g = V PCC /V 2 , respectively.…”
Section: Impedance Modelingmentioning
confidence: 99%
“…Thus, impedance modeling needs to take the influence of transformer configuration. Equation (9), moreover, (10) can be rewritten as (11) and (12) by supposing the turn ratios of the primary and secondary side are K r = V PCC /V 1 and K g = V PCC /V 2 , respectively.…”
Section: Impedance Modelingmentioning
confidence: 99%
“…12. Bode diagram of the DFIG system impedance and the series π sections weak network ZNET (a) two sections ZNET2; (b) three sections ZNET3, with CNET = 1.024 μF, RNET = 2.06 Ω, LNET = 36 mH in (5). Virtual impedance in (10) with ωc = 2000 rad/s, ωbp = 2π*1600 rad/s, Rv = 4e-9 Ω, Td = 300 μs Fig.…”
Section: Implementation Of Virtual Impedance In the Stator Branchmentioning
confidence: 99%
“…Other methods need stator voltage decomposition into positive and negative sequence, in order to deal with them separately to meet the specific control targets . Some of the proposed approaches are based on oversimplifications, where assumptions were made that during voltage imbalance, unbalanced voltage vector pulsation has constant value, which is not true because it contains double grid frequency component.…”
Section: Introductionmentioning
confidence: 99%
“…Other methods need stator voltage decomposition into positive and negative sequence, in order to deal with them separately to meet the specific control targets. [7][8][9] Some of the proposed approaches are based on oversimplifications, 10 where assumptions were made that during voltage imbalance, unbalanced voltage vector pulsation has constant value, which is not true because it contains double grid frequency component. In Iwanski et al, 11 the virtual torque-based control method of three-phase rectifier has been proposed, whereas the grid has been treated as the virtual machine similarly to the well-known virtual flux oriented control method.…”
mentioning
confidence: 99%