2019
DOI: 10.1016/j.jmr.2019.04.007
|View full text |Cite
|
Sign up to set email alerts
|

Modular transmission line probes for microfluidic nuclear magnetic resonance spectroscopy and imaging

Abstract: Microfluidic NMR spectroscopy can probe chemical and bio-chemical processes non-invasively in a tightly controlled environment. We present a dual-channel modular probe assembly for high efficiency microfluidic NMR spectroscopy and imaging. It is compatible with a wide range of microfluidic devices, without constraining the fluidic design. It collects NMR signals from a designated sample volume on the device with high sensitivity and resolution. Modular design allows adapting the detector geometry to different … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
34
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2

Relationship

5
3

Authors

Journals

citations
Cited by 22 publications
(36 citation statements)
references
References 37 publications
0
34
0
Order By: Relevance
“…The assembled microfluidic device was put in a transmission line based home-built probe. 11 The device sits between the two detector planes with the sample chamber of the device aligned with the sensitive area of the detector. All NMR experiments were performed at a field strength of 11.7 T with an AVANCE III console.…”
Section: Methodsmentioning
confidence: 99%
“…The assembled microfluidic device was put in a transmission line based home-built probe. 11 The device sits between the two detector planes with the sample chamber of the device aligned with the sensitive area of the detector. All NMR experiments were performed at a field strength of 11.7 T with an AVANCE III console.…”
Section: Methodsmentioning
confidence: 99%
“…Highly efficient NMR micro-detectors have been developed by a number of groups over the past two decades [12][13][14][15][16][17][18][19] and sensitivities in the vicinity of 1 nmol √ s have been achieved with samples around 1 µL volume 20 . Our group has recently presented a modular microfluidic NMR system based on this detector geometry that accommodates generic LoC devices 21 . A detailed characterisation of its performance is given in Ref.…”
Section: Introductionmentioning
confidence: 99%
“…Highly efficient NMR micro-detectors have been developed by a number of groups over the past two decades [5][6][7][8][9][10][11][12] and sensitivities in the vicinity of 1 nmol √ s have been achieved with samples around 1 µL volume [13]. Our group have recently presented a modular microfluidic NMR system that accommodates generic LoC devices [14]. In the present contribution, we show that this makes it possible to quantitatively follow the metabolic activity of as few as 1250 mammalian cells in 2.5 µL of medium over the course of 48h.…”
mentioning
confidence: 99%
“…In the present study, we demonstrate that a flexible microfluidic NMR platform can be used to quantitatively compare metabolic data obtained under different experimental modalities. The platform consists of a modular transmission line NMR micro-probe [14] in combination with disposable, generic LoC devices. Human adenocarcinoma cells (MCF-7) [27] were cultured under hypoxic conditions in LoC devices which were coated either with fibronectin, in order to promote adhesion of the cells to the chip surface [28], or with pluronic F-127, which prevents cell adhesion and forces the cells to form a spheroid [29].…”
mentioning
confidence: 99%
See 1 more Smart Citation