2019
DOI: 10.1016/j.jmr.2019.06.003
|View full text |Cite
|
Sign up to set email alerts
|

Modular imaging system: Rapid scan EPR at 800 MHz

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(14 citation statements)
references
References 47 publications
0
12
0
Order By: Relevance
“…Work at the University of Denver along with the University of Maryland [ 7 12 ], the Ohio State University [ 13 – 18 ], Dartmouth [ 19 23 ], the University of Chicago [ 24 42 ], and the NIH [ 43 51 ] continues to demonstrate the utility of low-field EPR for pre-clinical EPR imaging. Expansion of these efforts continues at West Virginia University under the guidance of Tseytlin, Driesschaert and Khramtsov [ 52 55 ]. Low-field EPR spectroscopy and imaging applied to pre-clinical applications forms an outstanding basis from which to build in-field applications of materials analysis and non-destructive evaluation (NDE).…”
Section: Contributions To the Low Magnetic Field At The University Ofmentioning
confidence: 99%
See 1 more Smart Citation
“…Work at the University of Denver along with the University of Maryland [ 7 12 ], the Ohio State University [ 13 – 18 ], Dartmouth [ 19 23 ], the University of Chicago [ 24 42 ], and the NIH [ 43 51 ] continues to demonstrate the utility of low-field EPR for pre-clinical EPR imaging. Expansion of these efforts continues at West Virginia University under the guidance of Tseytlin, Driesschaert and Khramtsov [ 52 55 ]. Low-field EPR spectroscopy and imaging applied to pre-clinical applications forms an outstanding basis from which to build in-field applications of materials analysis and non-destructive evaluation (NDE).…”
Section: Contributions To the Low Magnetic Field At The University Ofmentioning
confidence: 99%
“…Work at the University of Denver along with the University of Maryland [7][8][9][10][11][12], the Ohio State University [13][14][15][16][17][18], Dartmouth [19][20][21][22][23], the University of Chicago [24][25][26][27][28][29][30][31][32][33][34][35][36][37][38][39][40][41][42], and the NIH [43][44][45][46][47][48][49][50][51] continues to demonstrate the utility of low-field EPR for pre-clinical EPR imaging. Expansion of these efforts continues at West Virginia University under the guidance of Tseytlin, Driesschaert and Khramtsov [52][53][54]…”
Section: Contributions To the Low Magnetic Field At The University Of Denvermentioning
confidence: 99%
“…The original in vivo pulse EPR P O 2 imaging technique is due to the group of Murali Krisha at the National Cancer Institute (Bourg et al 1993). Recent in vivo spectral spatial images using rapid scan EPR have been developed by the Khramtsov group at West Virginia University (Tseytlin et al 2019).…”
Section: Fundamentals Of Epr Imagingmentioning
confidence: 99%
“…A duration of field scanning of 3.8 milliseconds has been reported in state-of-the-art CW-EPR imaging (39). Moreover, rapid-scan EPR detection was developed and has been demonstrated to be a faster means of image acquisition (47). However, such state-of-theart hardware for EPR spectroscopy and imaging is available at only a few instrumentdevelopment laboratories.…”
Section: Introductionmentioning
confidence: 99%